Publication:
A novel and easy-to-construct polymeric L-glutamic acid-modified sensor for urinary 1-hydroxypyrene detection: Human biomonitoring of polycyclic aromatic hydrocarbons exposure

dc.contributor.authorThangphatthanarungruang J.
dc.contributor.authorChotsuwan C.
dc.contributor.authorSiangproh W.
dc.contributor.otherSrinakharinwirot University
dc.date.accessioned2023-11-15T02:08:14Z
dc.date.available2023-11-15T02:08:14Z
dc.date.issued2023
dc.date.issuedBE2566
dc.description.abstract1-Hydroxypyrene (1-OHP), a metabolite of polycyclic aromatic hydrocarbons (PAHs), is a frequently used biomarker for assessing human exposure to PAHs. Therefore, the technology that provides a quick, simple, cost-effective, portable, accurate, precise, and reliable test is still in great demand. To the best of our knowledge, the creation of an electrochemical device based on poly(L-glutamic acid)-modified a screen-printed graphene electrode (poly(L-GA)/SPGE) for 1-OHP detection was described for the first time. The developed sensor was simply and rapidly manufactured via only a single step of electropolymerization. All the concerned parameters and electroanalytical conditions were studied to obtain the best performance of the methodology. Under optimal conditions, the 1-OHP sensing provided a linear range of 1–1000 nM with the limits of detection and quantification of 0.95 and 3.16 nM, respectively. Moreover, this developed sensor was successfully utilized by determining 1-OHP in human urine samples. In comparison with conventional methods, this newly proposed electrochemical methodology might be tremendously valuable for 1-OHP evaluation in environmental and occupational applications, leading to the early detection of illness risk linked to PAHs in the human body. © 2022 Elsevier B.V.
dc.format.mimetypeapplication/pdf
dc.identifier.citationTalanta. Vol 253, No. (2023)
dc.identifier.doi10.1016/j.talanta.2022.123929
dc.identifier.urihttps://hdl.handle.net/20.500.14740/12523
dc.publisherElsevier B.V.
dc.rights.holderScopus
dc.subject.other1-Hydroxypyrene
dc.subject.otherElectrochemical sensor
dc.subject.otherPoly(L-glutamic acid)
dc.subject.otherPolycyclic aromatic hydrocarbons
dc.subject.otherScreen-printed graphene electrode
dc.titleA novel and easy-to-construct polymeric L-glutamic acid-modified sensor for urinary 1-hydroxypyrene detection: Human biomonitoring of polycyclic aromatic hydrocarbons exposure
dc.typeArticle
dspace.entity.typePublication
swu.datasource.scopushttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85137715644&doi=10.1016%2fj.talanta.2022.123929&partnerID=40&md5=b143ffc551d94a832a395971cc6e8b0a

Files