Publication:
A new alternative assay for sensitive analysis of ethylenethiourea and propylenethiourea in fruit samples after their separation

dc.contributor.authorNantaphol S.
dc.contributor.authorMoonla C.
dc.contributor.authorPromvichai S.
dc.contributor.authorTangkuaram T.
dc.contributor.authorChailapakul O.
dc.contributor.authorSiangproh W.
dc.date.accessioned2021-04-05T03:01:19Z
dc.date.available2021-04-05T03:01:19Z
dc.date.issued2020
dc.date.issuedBE2563
dc.description.abstractUltra-high-performance liquid chromatography (UHPLC) coupled with a cobalt phthalocyanine screen-printed carbon electrode (CoPc-SPCE) was developed and validated for quantitative analysis of ethylenethiourea (ETU) and propylenethiourea (PTU). CoPC-SPCE provided high catalytic properties for ETU and PTU oxidation. This fabricated electrode is inexpensive, disposable, and easy to prepare by an in-house screen-printing technique. The chromatographic separation was performed in isocratic mode on a reversed phase C18 (100 mm × 4.6 mm, 3 µm) column, using a 90?:?10 (v/v) ratio of 0.05 M phosphate buffer solution (pH 4) and methanol as the mobile phase with a flow rate of 1.0 mL min-1 at an oxidation potential of +0.7 V vs. Ag/AgCl. The separation could be achieved within 3 min, and a wide linear range of 0.01-100 µg mL-1 (r2 > 0.99) was obtained for both analytes. The limits of detection (3 S/N) were found to be 0.006 and 0.009 µg mL-1 for ETU and PTU, respectively. Furthermore, this proposed method was utilized to determine ETU and PTU in fruit samples with satisfactory results, yielding excellent intra-day and inter-day relative standard deviations and recoveries. These results demonstrated that the proposed assay can be used as a new alternative way for inexpensive, rapid, selective and sensitive determination of ETU and PTU in fruit samples. © The Royal Society of Chemistry.
dc.format.mimetypeapplication/pdf
dc.identifier.citationAnalytical Methods. Vol 12, No.29 (2020), p.3705-3712
dc.identifier.doi10.1039/d0ay01001d
dc.identifier.issn17599660
dc.identifier.other2-s2.0-85089505220
dc.identifier.urihttps://hdl.handle.net/20.500.14740/4431
dc.rights.holderScopus
dc.subject.otherCatalytic oxidation
dc.subject.otherElectrodes
dc.subject.otherHigh performance liquid chromatography
dc.subject.otherHigh pressure liquid chromatography
dc.subject.otherScreen printing
dc.subject.otherChromatographic separations
dc.subject.otherCobalt phthalocyanine
dc.subject.otherPhosphate buffer solutions
dc.subject.otherPropylenethiourea (PTU)
dc.subject.otherRelative standard deviations
dc.subject.otherScreen printing technique
dc.subject.otherScreen-printed carbon electrodes
dc.subject.otherUltra high performance liquid chromatography (UHPLC)
dc.subject.otherFruits
dc.titleA new alternative assay for sensitive analysis of ethylenethiourea and propylenethiourea in fruit samples after their separation
dc.typeArticle
dspace.entity.typePublication
swu.datasource.scopushttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85089505220&doi=10.1039%2fd0ay01001d&partnerID=40&md5=749ed2d7a057d763fc5a1a17cccedd34

Files