Publication: Pulsed amperometry for anti-fouling of boron-doped diamond in electroanalysis of β-agonists: Application to flow injection for pharmaceutical analysis
| dc.contributor.author | Karuwan C. | |
| dc.contributor.author | Mantim T. | |
| dc.contributor.author | Chaisuwan P. | |
| dc.contributor.author | Wilairat P. | |
| dc.contributor.author | Grudpan K. | |
| dc.contributor.author | Jittangprasert P. | |
| dc.contributor.author | Einaga Y. | |
| dc.contributor.author | Chailapakul O. | |
| dc.contributor.author | Suntornsuk L. | |
| dc.contributor.author | Anurukvorakun O. | |
| dc.contributor.author | Nacapricha D. | |
| dc.date.accessioned | 2021-04-05T04:32:26Z | |
| dc.date.available | 2021-04-05T04:32:26Z | |
| dc.date.issued | 2006 | |
| dc.date.issuedBE | 2549 | |
| dc.description.abstract | This work presents the construction and application of boron-doped diamond (BDD) thin film electrode as sensor for the determination of three β-agonists, viz. salbutamol, terbutaline and clenbuterol. Although well-known as a chemically inert material, BDD film however shows fouling in detection of these compounds using fixed-potential mode amperometry. A suitable waveform for pulsed amperometric detection (PAD) was developed and used to determine the agonist compounds. It was seen that the developed PAD significantly refreshed the BDD surface for long-term detection in flow injection analysis. Linear working ranges were 0.5-100 μM, 1.0-100 μM and 0.5-50 μM for salbutamol, terbutaline and clenbuterol, respectively. The developed PAD-BDD system was applied to successfully determine salbutamol and terbutaline in commercial pharmaceutical products. The methods were validated with a capillary electrophoresis method. © 2006 by MDPI. | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.citation | Sensors. Vol 6, No.12 (2006), p.1837-1850 | |
| dc.identifier.doi | 10.3390/s6121837 | |
| dc.identifier.issn | 14243210 | |
| dc.identifier.other | 2-s2.0-33947367459 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14740/6002 | |
| dc.rights.holder | มหาวิทยาลัยศรีนครินทรวิโรฒ | |
| dc.subject.other | Capillary electrophoresis | |
| dc.subject.other | Diamonds | |
| dc.subject.other | Boron doped diamond | |
| dc.subject.other | Flow injection | |
| dc.subject.other | Flow injection analysis | |
| dc.subject.other | Pharmaceutical analysis | |
| dc.subject.other | Pharmaceutical products | |
| dc.subject.other | Pulsed amperometric detection | |
| dc.subject.other | Pulsed amperometry | |
| dc.subject.other | Thin-film electrode | |
| dc.subject.other | Boolean functions | |
| dc.title | Pulsed amperometry for anti-fouling of boron-doped diamond in electroanalysis of β-agonists: Application to flow injection for pharmaceutical analysis | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| swu.datasource.scopus | https://www.scopus.com/inward/record.uri?eid=2-s2.0-33947367459&doi=10.3390%2fs6121837&partnerID=40&md5=482d3a4febd812dc93ccff22e3ae48dc |
