Publication: Transparent Cross-Flow Platform as Chemiluminescence Detection Cell in Cross Injection Analysis
| dc.contributor.author | Somboonsuk T. | |
| dc.contributor.author | Saetear P. | |
| dc.contributor.author | Mantim T. | |
| dc.contributor.author | Ratanawimarnwong N. | |
| dc.contributor.author | Wilairat P. | |
| dc.contributor.author | Choengchan N. | |
| dc.contributor.author | Nacapricha D. | |
| dc.contributor.other | Srinakharinwirot University | |
| dc.date.accessioned | 2023-11-15T02:08:17Z | |
| dc.date.available | 2023-11-15T02:08:17Z | |
| dc.date.issued | 2023 | |
| dc.date.issuedBE | 2566 | |
| dc.description.abstract | This work presents the use of a transparent ‘Cross Injection Analysis’ (CIA) platform as a flow system for chemiluminescence (CL) measurements. The CL-CIA flow device incorporates introduction channels for samples and reagents, and the reaction and detection channels are in one acrylic unit. A photomultiplier tube placed above the reaction channel detects the emitted luminescence. The system was applied to the analysis of (i) Co(II) via the Co(II)-catalyzed H2O2-luminol reaction and (ii) paracetamol via its inhibitory effect on the catalytic activity of Fe(CN)63− on the H2O2-luminol reaction. A linear calibration was obtained for Co(II) in the range of 0.002 to 0.025 mg L−1 Co(II) (r2 = 0.9977) for the determination of Co(II) in water samples. The linear calibration obtained for the paracetamol was 10 to 200 mg L−1 (r2 = 0.9906) for the determination of pharmaceutical products. The sample throughput was 60 samples h−1. The precision was ≤4.2% RSD. The consumption of the samples and reagents was ca. 170 µL per analysis cycle. © 2023 by the authors. | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.citation | Molecules. Vol 28, No.3 (2023) | |
| dc.identifier.doi | 10.3390/molecules28031316 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14740/12607 | |
| dc.publisher | MDPI | |
| dc.rights.holder | Scopus | |
| dc.subject.other | Chemiluminescence | |
| dc.subject.other | Cobalt | |
| dc.subject.other | Cross injection analysis | |
| dc.subject.other | Cross-flow | |
| dc.subject.other | Paracetamol | |
| dc.title | Transparent Cross-Flow Platform as Chemiluminescence Detection Cell in Cross Injection Analysis | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| swu.datasource.scopus | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85147895656&doi=10.3390%2fmolecules28031316&partnerID=40&md5=0915fa72f90ece19f38cd28704f6045f |
