Publication:
Simultaneous injection effective mixing flow analysis of urinary albumin using dye-binding reaction

dc.contributor.authorRatanawimarnwong N.
dc.contributor.authorPonhong K.
dc.contributor.authorTeshima N.
dc.contributor.authorNacapricha D.
dc.contributor.authorGrudpan K.
dc.contributor.authorSakai T.
dc.contributor.authorMotomizu S.
dc.date.accessioned2021-04-05T03:34:05Z
dc.date.available2021-04-05T03:34:05Z
dc.date.issued2012
dc.date.issuedBE2555
dc.description.abstractA new four-channel simultaneous injection effective mixing flow analysis (SIEMA) system has been assembled for the determination of urinary albumin. The SIEMA system consisted of a syringe pump, two 5-way cross connectors, four holding coils, five 3-way solenoid valves, a 50-cm long mixing coil and a spectrophotometer. Tetrabromophenol blue anion (TBPB) in Triton X-100 micelle reacted with albumin at pH 3.2 to form a blue ion complex with a λmax 625 nm. TBPB, Triton X-100, acetate buffer and albumin standard solutions were aspirated into four individual holding coils by a syringe pump and then the aspirated zones were simultaneously pushed in the reverse direction to the detector flow cell. Baseline drift, due to adsorption of TBPB-albumin complex on the wall of the hydrophobic PTFE tubing, was minimized by aspiration of Triton X-100 and acetate buffer solutions between samples. The calibration graph was linear in the range of 10-50 μg/mL and the detection limit for albumin (3σ) was 0.53 μg/mL. The RSD (n = 11) at 30 μg/mL was 1.35%. The sample throughput was 37/h. With a 10-fold dilution, interference from urine matrix was removed. The proposed method has advantages in terms of simple automation operation and short analysis time. © 2012 Elsevier B.V. All rights reserved.
dc.format.mimetypeapplication/pdf
dc.identifier.citationTalanta. Vol 96, No. (2012), p.50-54
dc.identifier.doi10.1016/j.talanta.2012.02.027
dc.identifier.issn399140
dc.identifier.other2-s2.0-84864281015
dc.identifier.urihttps://hdl.handle.net/20.500.14740/7008
dc.rights.holderมหาวิทยาลัยศรีนครินทรวิโรฒ
dc.subject.otherBody fluids
dc.subject.otherSolenoid valves
dc.subject.otherSyringes
dc.subject.otherAcetate buffer solutions
dc.subject.otherAlbumin
dc.subject.otherAutomation operation
dc.subject.otherMixing analysis
dc.subject.otherSimultaneous injections
dc.subject.otherTetrabromophenol blue
dc.subject.otherTriton X-100 micelle
dc.subject.otherUrine
dc.subject.otherMixing
dc.titleSimultaneous injection effective mixing flow analysis of urinary albumin using dye-binding reaction
dc.typeConference Paper
dspace.entity.typePublication
swu.datasource.scopushttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84864281015&doi=10.1016%2fj.talanta.2012.02.027&partnerID=40&md5=022e08925ac05680df5d04266277d560

Files