Publication:
Influence of stress-relieving heat treatments on the efficacy of Co-Cr-Mo-W alloy copings fabricated using selective laser melting

dc.contributor.authorHtat H.L.
dc.contributor.authorTakaichi A.
dc.contributor.authorKajima Y.
dc.contributor.authorKittikundecha N.
dc.contributor.authorKamijo S.
dc.contributor.authorHanawa T.
dc.contributor.authorWakabayashi N.
dc.contributor.correspondenceHtat H.L.
dc.contributor.otherSrinakharinwirot University
dc.date.accessioned2025-05-28T07:56:06Z
dc.date.issued2024-01-01
dc.date.issuedBE2567-01-01
dc.description.abstractPurpose: This study aimed to evaluate the influence of stress-relieving heat treatments on the metal-ceramic bond strength and fitness accuracy of selective laser melting (SLM)-fabricated Co-Cr alloy copings. Methods: SLM-manufactured Co-Cr samples were stress-relieved at 750 (Ht-750) and 1150 °C (Ht-1150). The microstructure, surface roughness, metal-ceramic bond strength, marginal and internal fit, Vickers hardness, and residual stress were then compared with those of the non-heat-treated group (As-built). The results were analyzed using one-way ANOVA and post-hoc tests (Tukey’s or Student’s t test) (P = 0.05). Results: The microstructure of the Ht-1150 samples had a brittle oxide layer and lower surface roughness, resulting in significantly lower bond strength values than those of the other groups. The As-built group exhibited significantly lower marginal gap values than the Ht-750 and Ht-1150 groups. Therefore, the post-heat treatments degraded the marginal fitness. The surface residual stress in all sample groups were compressive because of the sandblasting effect. The compressive stresses were larger in Ht-1150 than in As-built and Ht-750 owing to their low hardness values. Conclusions: Stress-relief annealing porcelain-fused-to-metal single crowns does not improve bond strength and degrades fitness accuracy because additional post-heat treatments induce thermal distortion. These findings are expected to facilitate the direct application of As-built SLM single crowns in dentistry to minimize post-manufacturing costs and time.
dc.identifier.citationJournal of Prosthodontic Research Vol.68 No.2 (2024) , 310-318
dc.identifier.doi10.2186/jpr.JPR_D_22_00283
dc.identifier.eissn22124632
dc.identifier.issn18831958
dc.identifier.pmid37438109
dc.identifier.scopus2-s2.0-85190312344
dc.identifier.urihttps://hdl.handle.net/20.500.14740/20628
dc.rights.holderSCOPUS
dc.subjectDentistry
dc.titleInfluence of stress-relieving heat treatments on the efficacy of Co-Cr-Mo-W alloy copings fabricated using selective laser melting
dc.typeArticle
dspace.entity.typePublication
oaire.citation.endPage318
oaire.citation.issue2
oaire.citation.startPage310
oaire.citation.titleJournal of Prosthodontic Research
oaire.citation.volume68
oairecerif.author.affiliationInstitute of Science Tokyo
oairecerif.author.affiliationGraduate School of Medical and Dental Sciences
oairecerif.author.affiliationSrinakharinwirot University
swu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85190312344&origin=inward

Files