Publication:
Simple in-house flow-injection capillary electrophoresis with capacitively coupled contactless conductivity method for the determination of colistin

dc.contributor.authorChaisuwan P.
dc.contributor.authorMoonta T.
dc.contributor.authorSangcakul A.
dc.contributor.authorNacapricha D.
dc.contributor.authorWilairat P.
dc.contributor.authorUraisin K.
dc.date.accessioned2021-04-05T03:25:56Z
dc.date.available2021-04-05T03:25:56Z
dc.date.issued2015
dc.date.issuedBE2558
dc.description.abstractAn in-house flow-injection capillary electrophoresis with capacitively coupled contactless conductivity detection method was developed for the direct measurement of colistin in pharmaceutical samples. The flow injection and capillary electrophoresis systems are connected by an acrylic interface. Capillary electrophoresis separation is achieved within 2 min using a background electrolyte solution of 5 mM 2-morpholinoethanesulfonic acid and 5 mM histidine (pH 6). The flow-injection section allows for convenient filling of the capillary and sample introduction without the use of a pressure/vacuum manifold. Capacitively coupled contactless conductivity detection is employed since colistin has no chromophore but is cationic at pH 6. Calibration curve is linear from 20 to 150 mg/L, with a correlation coefficient (r2) of 0.997. The limit of quantitation is 20 mg/L. The developed method provides precision, simplicity, and short analysis time. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
dc.format.mimetypeapplication/pdf
dc.identifier.citationJournal of Separation Science. Vol 38, No.6 (2015), p.1035-1041
dc.identifier.doi10.1002/jssc.201401101
dc.identifier.issn16159306
dc.identifier.other2-s2.0-84925349843
dc.identifier.urihttps://hdl.handle.net/20.500.14740/6168
dc.rights.holderมหาวิทยาลัยศรีนครินทรวิโรฒ
dc.subject.otherAmino acids
dc.subject.otherChromophores
dc.subject.otherBack ground electrolyte
dc.subject.otherCapacitively coupled contactless conductivity detection
dc.subject.otherCapillary electrophoresis separation
dc.subject.otherColistin
dc.subject.otherCorrelation coefficient
dc.subject.otherFlow injection
dc.subject.otherLimit of quantitations
dc.subject.otherPolymyxin E
dc.subject.otherCapillary electrophoresis
dc.subject.other2 morpholinoethanesulfonic acid
dc.subject.otherAmino acid
dc.subject.otherColistin
dc.subject.otherHistidine
dc.subject.otherUnclassified drug
dc.subject.otherAntiinfective agent
dc.subject.otherColistin
dc.subject.otherArticle
dc.subject.otherCapillary electrophoresis
dc.subject.otherChromatophore
dc.subject.otherConductance
dc.subject.otherDrug determination
dc.subject.otherFlow injection capillary electrophoresis
dc.subject.otherHydrodynamics
dc.subject.otherLimit of quantitation
dc.subject.otherMembrane filter
dc.subject.otherPH
dc.subject.otherPriority journal
dc.subject.otherCapillary electrophoresis
dc.subject.otherDevices
dc.subject.otherEvaluation study
dc.subject.otherFlow injection analysis
dc.subject.otherProcedures
dc.subject.otherAnti-Bacterial Agents
dc.subject.otherColistin
dc.subject.otherElectrophoresis, Capillary
dc.subject.otherFlow Injection Analysis
dc.titleSimple in-house flow-injection capillary electrophoresis with capacitively coupled contactless conductivity method for the determination of colistin
dc.typeArticle
dspace.entity.typePublication
swu.datasource.scopushttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84925349843&doi=10.1002%2fjssc.201401101&partnerID=40&md5=b8648405c70a539399172c111f4e8f4b

Files