Publication:
Alternative method for measurement of albumin/creatinine ratio using spectrophotometric sequential injection analysis

dc.contributor.authorSiangproh W.
dc.contributor.authorTeshima N.
dc.contributor.authorSakai T.
dc.contributor.authorKatoh S.
dc.contributor.authorChailapakul O.
dc.date.accessioned2021-04-05T04:32:09Z
dc.date.available2021-04-05T04:32:09Z
dc.date.issued2009
dc.date.issuedBE2552
dc.description.abstractA simple, automatic and practical system for successive determination of albumin and creatinine has been developed by combining sequential injection analysis (SIA) and highly sensitive dye-binding assays. Albumin detection was based on the increase in the absorbance due to complex formation between albumin and eosin Y in acidic media. The absorbance of the complex was monitored at 547 nm. For the creatinine assay, the concentration of creatinine was measured by reaction with alkaline picrate to form a colored product which absorbs at 500 nm. The influences of experimental variables such as effects of pH, reagent concentration, standard/sample volume and interferences were investigated. Under optimal conditions, the automated method showed linearity up to 20 mg L-1 for albumin and 100 mg L-1 for creatinine. The 3σ detection limits were 0.6 and 3.5 mg L-1 for albumin and creatinine, respectively, and the relative standard deviations (n = 10) were 2.49% for 20 mg L-1 albumin, and 3.14% for 20 mg L-1 creatinine. Application of the proposed method to the direct analysis of urinary samples yielded results which agreed with those obtained from the Bradford protein assay and a creatinine enzymatic assay according to a paired t-test. The results obtained should be a step towards developing a fully automated and reliable analytical system for clinical research, which requires direct determination of albumin and creatinine and/or its ratios. © 2009 Elsevier B.V. All rights reserved.
dc.format.mimetypeapplication/pdf
dc.identifier.citationTalanta. Vol 79, No.4 (2009), p.1111-1117
dc.identifier.doi10.1016/j.talanta.2008.12.068
dc.identifier.issn399140
dc.identifier.other2-s2.0-67650497907
dc.identifier.urihttps://hdl.handle.net/20.500.14740/4434
dc.rights.holderScopus
dc.subject.otherAlkalinity
dc.subject.otherClinical research
dc.subject.otherSpectrophotometry
dc.subject.otherAlbumin
dc.subject.otherAlbumin/creatinine ratio (ACR)
dc.subject.otherCreatinine
dc.subject.otherSequential injection
dc.subject.otherUrinary
dc.subject.otherAssays
dc.titleAlternative method for measurement of albumin/creatinine ratio using spectrophotometric sequential injection analysis
dc.typeArticle
dspace.entity.typePublication
swu.datasource.scopushttps://www.scopus.com/inward/record.uri?eid=2-s2.0-67650497907&doi=10.1016%2fj.talanta.2008.12.068&partnerID=40&md5=03a6427546a8963fb36b4f0ac9631d9e

Files