Publication:
Radiation doses to patients in coronary interventions in a hospital in Thailand

dc.contributor.authorRoongsangmanoon W.
dc.contributor.authorSrimahachota S.
dc.contributor.authorKrisanachinda A.
dc.contributor.authorRehani M.
dc.date.accessioned2021-04-05T03:34:00Z
dc.date.available2021-04-05T03:34:00Z
dc.date.issued2012
dc.date.issuedBE2555
dc.description.abstractBackground: Radiation dose is best estimated by the Dose Area Product (DAP), the absorbed dose to air, multiplied by the X-ray beam cross-sectional area at the point of measurement. Interventional cardiologists should be made aware of the exposures to patients and how they compare to established norms. Objective: We assessed patient doses during coronary diagnostic and interventions then compared doses between two angiocardiographic systems in our center and through these actions. Methods and Results: In total, 308 (44.4%) diagnostic CAs, 229 (33.0%) one-vessel PCIs, 53 (7.6%) two or threevessel PCIs, and 15 (2.2%) PCIs to CTO were carried out. The mean DAP value for diagnostic CAs in room No. 1 (Siemens Axiom Artis dBC) was 45.2±28.7 Gy.cm 2, compared with room No. 2 (Philips Allura Xper biplane FD 20/10) where mean DAP value was 78.6±58.4 Gy.cm2 ( p < 0.001). The mean DAP value for one-vessel PCIs in room No. 1 was 97.8±67.5 Gy.cm2, compared with room No. 2, mean DAP value of 159.4±82.4 Gy.cm2 (p = 0.030). The mean DAP value for two or three-vessel PCIs in room No. 1 was 153.1±65.6 Gy.cm2, compared with room No. 2, mean DAP value of 168.0±94.7 Gy.cm2 (p = 0.070). DAP values per procedure in diagnostic CAs, one-vessel PCIs, and two or three-vessel PCIs in room No. 2 were higher than in room No. 1 after multivariable correction for weight and fluoroscopy time. Conclusions: Regular measurement of patient doses is an essential step to optimize exposure. It makes operators aware their own performance and allows comparisons with generally accepted practice.
dc.format.mimetypeapplication/pdf
dc.identifier.citationAsian Biomedicine. Vol 6, No.4 (2012), p.565-571
dc.identifier.doi10.5372/1905-7415.0604.091
dc.identifier.issn19057415
dc.identifier.other2-s2.0-84871706210
dc.identifier.urihttps://hdl.handle.net/20.500.14740/6987
dc.rights.holderมหาวิทยาลัยศรีนครินทรวิโรฒ
dc.subject.otherAdult
dc.subject.otherAged
dc.subject.otherAngiocardiography
dc.subject.otherArticle
dc.subject.otherFemale
dc.subject.otherFluoroscopy
dc.subject.otherHuman
dc.subject.otherMajor clinical study
dc.subject.otherMale
dc.subject.otherPercutaneous coronary intervention
dc.subject.otherRadiation dose
dc.subject.otherRadiation safety
dc.titleRadiation doses to patients in coronary interventions in a hospital in Thailand
dc.typeArticle
dspace.entity.typePublication
swu.datasource.scopushttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84871706210&doi=10.5372%2f1905-7415.0604.091&partnerID=40&md5=91327108ce1afe2ceff571c3e136c7ca