Publication:
Development of the rapid test kit for the identification of Campylobacter spp. Based on Loop-mediated Isothermal Amplification (LAMP) in combination with a Lateral Flow Dipstick (LFD) and Gold Nano-DNA Probe (AuNPs)

dc.contributor.authorThongphueak D.
dc.contributor.authorChansiri K.
dc.contributor.authorSriyapai T.
dc.contributor.authorAreekit S.
dc.contributor.authorSantiwatanakul S.
dc.contributor.authorWangroongsarb P.
dc.date.accessioned2021-04-05T03:03:58Z
dc.date.available2021-04-05T03:03:58Z
dc.date.issued2019
dc.date.issuedBE2562
dc.description.abstractThe detection of Campylobacter spp. in meat products was developed by using loop-mediated isothermal amplification (LAMP) combined with DNA-based bioassay methods, including a lateral-flow dipstick (LFD) and gold nano-DNA probe (AuNPs) assay. The LAMP primers were designed from the conserved nucleotide regions of Campylobacter spp. The analytical sensitivity of the LAMP-LFD and LAMP-AuNPs analysis was 360 fg/μl. The analytical specificity of LAMP-based assays showed no cross-reactions to Listeria monocytogenes, Salmonella Typhimurium, Escherichia coli, Bacillus cereus, Pseudomonas aeruginosa, Staphylococcus aureus, Enterobacter aerogenes, Serratia marcescens, Vibrio parahaemolyticus, Vibrio cholerae, Klebsiella oxytoca and Citrobacter diversus. The sensitivity, specificity and accuracy of both LAMP-LFD and LAMP-AuNPs for the detection of pre-enrichment cultures from raw chicken meat samples were 100%, 95% and 96.67%, respectively. Since the processing time of LAMP-based assays is 60-90 minutes, it is applicable as a point-of-care screening test for food safety and as a process control of Campylobacter spp. contamination. © 2019 Thammasat University. All rights reserved.
dc.format.mimetypeapplication/pdf
dc.identifier.citationScience and Technology Asia. Vol 24, No.1 (2019), p.63-71
dc.identifier.doi10.14456/scitechasia.2019.7
dc.identifier.issn25869027
dc.identifier.other2-s2.0-85066736783
dc.identifier.urihttps://hdl.handle.net/20.500.14740/5514
dc.rights.holderScopus
dc.titleDevelopment of the rapid test kit for the identification of Campylobacter spp. Based on Loop-mediated Isothermal Amplification (LAMP) in combination with a Lateral Flow Dipstick (LFD) and Gold Nano-DNA Probe (AuNPs)
dc.typeArticle
dspace.entity.typePublication
swu.datasource.scopushttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85066736783&doi=10.14456%2fscitechasia.2019.7&partnerID=40&md5=4e67a8d25c78dcfb16bfd1bba8c79be1

Files