Effect of cooling water loop on the thermal performance of air conditioning system

dc.contributor.authorSiricharoenpanich A.
dc.contributor.authorWiriyasart S.
dc.contributor.authorPrurapark R.
dc.contributor.authorNaphon P.
dc.date.accessioned2021-04-05T03:02:26Z
dc.date.available2021-04-05T03:02:26Z
dc.date.issued2019
dc.date.issuedBE2562
dc.description.abstractThe aim of this research is to improve thermal performance of air conditioning system by cooling water loop. In experiment, the cooling water loop with the concentric helically coiled tube heat exchanger is installed between the compressor unit and condenser unit for cooling refrigerant before entering the condenser unit. Effects of water mass flow rate and atmospheric temperature on the COP are considered. The obtained results are compared with those from the conventional air conditioning system without cooling water loop. It can be seen that the COP tends to increase with increasing water mass flow rate and tend to decrease as atmospheric temperature increases. The highest COP is 31.02% as compared with the conventional reference system, respectively. In addition, not only COP of air conditioning system are increased but also the hot water storage is obtained which used for various applications. The results obtained this study are expected to lead to guidelines that will allow the improved thermal performance of air conditioning system and hot water storage system which reduce energy consumption. © 2019 The Authors.
dc.format.mimetypeapplication/pdf
dc.identifier.citationCase Studies in Thermal Engineering. Vol 15, (2019)
dc.identifier.doi10.1016/j.csite.2019.100518
dc.identifier.issn2214157X
dc.identifier.other2-s2.0-85071934313
dc.identifier.urihttps://hdl.handle.net/20.500.14740/5094
dc.rights.holderScopus
dc.subject.otherAir conditioning
dc.subject.otherAtmospheric movements
dc.subject.otherAtmospheric temperature
dc.subject.otherAtmospheric thermodynamics
dc.subject.otherCooling
dc.subject.otherEnergy utilization
dc.subject.otherMass transfer
dc.subject.otherOceanography
dc.subject.otherWater
dc.subject.otherCompressor units
dc.subject.otherConventional air-conditioning systems
dc.subject.otherCooling refrigerants
dc.subject.otherHelically coiled tubes
dc.subject.otherHot water storage
dc.subject.otherReduce energy consumption
dc.subject.otherReference systems
dc.subject.otherThermal Performance
dc.subject.otherCooling water
dc.titleEffect of cooling water loop on the thermal performance of air conditioning system