Publication:
In vivo estimation of the head tissue conductivities by electrical impedance tomography technique and positivity constraint

dc.contributor.authorOuypornkochagorn T.
dc.date.accessioned2021-04-05T03:22:00Z
dc.date.available2021-04-05T03:22:00Z
dc.date.issued2017
dc.date.issuedBE2560
dc.description.abstractReported head tissue conductivities to date are usually obtained from sample investigation in situ or in vitro. However, there are many issues to concern e.g. sample selection and preparation or the deterioration of physiological property over time. In vivo estimation is recently used to estimate based on certain techniques. Electrical impedance tomography (EIT) is a mentioned technique, however regarding the susceptibility to noise of EIT, the estimation often results unexpected outcome. The estimated conductivity values may be inaccurate and/or be negative. The number of tissues in the estimation is then usually not over two. In this work, positivity constraint was employed to restrain the estimate to be only positive. Simulation result shows that the employment of the constraint can improve estimation accuracy and robustness to noise and also modeling error. Simultaneous estimation for all five main tissues is possible as well, even though the estimation of the cerebrospinal fluid conductivity is still not accurate. ©2017 IEEE.
dc.format.mimetypeapplication/pdf
dc.identifier.citation2017 International Electrical Engineering Congress, iEECON 2017. (2017)
dc.identifier.doi10.1109/IEECON.2017.8075867
dc.identifier.other2-s2.0-85039947538
dc.identifier.urihttps://hdl.handle.net/20.500.14740/4050
dc.rights.holderScopus
dc.subject.otherCerebrospinal fluid
dc.subject.otherElectric impedance
dc.subject.otherElectric impedance measurement
dc.subject.otherElectric impedance tomography
dc.subject.otherHistology
dc.subject.otherTomography
dc.subject.otherElectrical impe dance tomography (EIT)
dc.subject.otherElectrical impedance tomography
dc.subject.otherIn-vivo
dc.subject.otherPhysiological properties
dc.subject.otherPosivity constraint
dc.subject.otherRobustness to noise
dc.subject.otherSimultaneous estimation
dc.subject.otherTissue conductivity
dc.subject.otherTissue
dc.titleIn vivo estimation of the head tissue conductivities by electrical impedance tomography technique and positivity constraint
dc.typeConference Paper
dspace.entity.typePublication
swu.datasource.scopushttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85039947538&doi=10.1109%2fIEECON.2017.8075867&partnerID=40&md5=5a4aa5c43425fa658520dd36a1625ab6

Files