Publication: Sodium dodecyl sulfate-modified electrochemical paper-based analytical device for determination of dopamine levels in biological samples
1
0
Issued Date
2012
Resource Type
File Type
application/pdf
ISSN
32670
Other identifier(s)
2-s2.0-84865552000
Rights Holder(s)
มหาวิทยาลัยศรีนครินทรวิโรฒ
Bibliographic Citation
Analytica Chimica Acta. Vol 744, No. (2012), p.1-7
Suggested Citation
Rattanarat P., Dungchai W., Siangproh W., Chailapakul O., Henry C.S. Sodium dodecyl sulfate-modified electrochemical paper-based analytical device for determination of dopamine levels in biological samples. Analytica Chimica Acta. Vol 744, No. (2012), p.1-7. doi:10.1016/j.aca.2012.07.003 Retrieved from: https://hdl.handle.net/20.500.14740/6968
Abstract
We report the development of an electrochemical paper-based analytical device (ePAD) for the selective determination of dopamine (DA) in model serum sample. The ePAD device consists of three layers. In the top layer, SU-8 photoresist defines a hydrophilic sample application spot on the filter paper. The middle layer was made from transparency film and contained two holes, one for sample preconcentration and the other for the surfactant to allow transfer to the third layer. A screen-printed carbon electrode formed the bottom layer and was used for electrochemical measurements. In the absence of the anionic surfactant, sodium dodecyl sulfate (SDS), the oxidation peaks of DA, ascorbic acid (AA) and uric acid (UA) overlapped. With the addition of SDS, the DA oxidation peak shifted to more negative values and was clearly distinguishable from AA and UA. The oxidation potential shift was presumably due to preferential electrostatic interactions between the cationic DA and the anionic SDS. Indeed, whilst the SDS-modified paper improved the DA current five-fold, the non-ionic Tween-20 and cationic tetradecyltrimethylammonium bromide surfactants had no effect or reduced the current, respectively. Furthermore, only the SDS-modified paper showed the selective shift in oxidation potential for DA. DA determination was carried out using square-wave voltammetry between -0.2 and 0.8. V vs. Ag/AgCl, and this ePAD was able to detect DA over a linear range of 1-100μM with a detection limit (S/N = 3) of 0.37μM. The ePAD seems suitable as a low cost, easy-to-use, portable device for the selective quantitation of DA in human serum samples. © 2012 Elsevier B.V..
Subject(s)
Ascorbic acids
Dopamine
ELectrochemical detection
Human serum
Paper-based analytical device
Sodium dodecyl sulfate
Uric acids
Amines
Analytic equipment
Anionic surfactants
Body fluids
Cationic surfactants
Diffusers (optical)
Ketones
Neurophysiology
Organic acids
Oxidation
Paper
Photoresists
Sulfur compounds
Voltammetry
Sodium sulfate
Ascorbic acid
Cationic surfactant
Dodecyl sulfate sodium
Dopamine
Silver
Silver chloride
Tetradecyltrimethylammonium bromide
Unclassified drug
Uric acid
Analytical equipment
Article
Blood sampling
Chemical interaction
Concentration (parameters)
Dopamine blood level
Dopamine metabolism
Electrochemical analysis
Electrochemical paper based analytical device
Film
Filter
Hydrophilicity
Limit of detection
Linear system
Oxidation
Paper
Potentiometry
Priority journal
Quantitative analysis
Static electricity
Dopamine
Electrochemical Techniques
Equipment Design
Humans
Paper
Sensitivity and Specificity
Sodium Dodecyl Sulfate
Amines
Amperometry
Ascorbic Acid
Electrochemistry
Layers
Organic Acids
Oxidation
Sodium Sulfate
Surfactants
Dopamine
ELectrochemical detection
Human serum
Paper-based analytical device
Sodium dodecyl sulfate
Uric acids
Amines
Analytic equipment
Anionic surfactants
Body fluids
Cationic surfactants
Diffusers (optical)
Ketones
Neurophysiology
Organic acids
Oxidation
Paper
Photoresists
Sulfur compounds
Voltammetry
Sodium sulfate
Ascorbic acid
Cationic surfactant
Dodecyl sulfate sodium
Dopamine
Silver
Silver chloride
Tetradecyltrimethylammonium bromide
Unclassified drug
Uric acid
Analytical equipment
Article
Blood sampling
Chemical interaction
Concentration (parameters)
Dopamine blood level
Dopamine metabolism
Electrochemical analysis
Electrochemical paper based analytical device
Film
Filter
Hydrophilicity
Limit of detection
Linear system
Oxidation
Paper
Potentiometry
Priority journal
Quantitative analysis
Static electricity
Dopamine
Electrochemical Techniques
Equipment Design
Humans
Paper
Sensitivity and Specificity
Sodium Dodecyl Sulfate
Amines
Amperometry
Ascorbic Acid
Electrochemistry
Layers
Organic Acids
Oxidation
Sodium Sulfate
Surfactants