Publication:
Effect of White Charcoal on COD Reduction in Wastewater Treatment

dc.contributor.authorPijarn N.
dc.contributor.authorButsee M.
dc.contributor.authorBuakul K.
dc.contributor.authorSeng H.
dc.contributor.authorSribuarai T.
dc.contributor.authorPhonprasert P.
dc.contributor.authorTaneeto K.
dc.contributor.authorAtthameth P.
dc.date.accessioned2021-04-05T03:22:10Z
dc.date.available2021-04-05T03:22:10Z
dc.date.issued2017
dc.date.issuedBE2560
dc.description.abstractThe objective of this study is to compare the COD reduction in wastewater between using coconut shell and coconut spathe white charcoal from Khlong Wat NongPra-Ong, Krathumbaen, SamutSakhon province, Thailand. The waste water samples were collected using composite sampling method. The experimental section can be divided into 2 parts. The first part was study the optimum of COD adsorption time using both white charcoals. The second part was study the optimum amount of white charcoal for chemical oxygen demand (COD) reduction. The pre-treatment of wastewater was examined in parameters include temperature, alkalinity (pH), conductivity, turbidity, suspended solid (SS), total dissolved solid (TDS), and COD. The results show that both white charcoals can reduce COD of wastewater. The pH of pre-treatment wastewater had pH 9 but post-treatment wastewaters using both white charcoals have pH 8. The COD of pre-treatment wastewater had COD as 258 mg/L but post-treatment wastewater using coconut shell white charcoal had COD steady at 40 mg/L in 30 min and the amount of white charcoals 4 g. The COD of post-treatment wastewater using coconut spathe white charcoal had COD steady at 71 mg/L in 30 min and the amount of white charcoals 4 g. Therefore comparison of COD reduction between coconut shell white charcoal versus coconut spathe white charcoal found that the coconut shell white charcoal had efficiency for COD reduction better than coconut spathe white charcoal. © Published under licence by IOP Publishing Ltd.
dc.format.mimetypeapplication/pdf
dc.identifier.citationIOP Conference Series: Materials Science and Engineering. Vol 216, No.1 (2017)
dc.identifier.doi10.1088/1757-899X/216/1/012002
dc.identifier.issn17578981
dc.identifier.other2-s2.0-85025822300
dc.identifier.urihttps://hdl.handle.net/20.500.14740/4127
dc.rights.holderมหาวิทยาลัยศรีนครินทรวิโรฒ
dc.subject.otherAlkalinity
dc.subject.otherCharcoal
dc.subject.otherChemical oxygen demand
dc.subject.otherShells (structures)
dc.subject.otherAdsorption time
dc.subject.otherCoconut shells
dc.subject.otherComposite sampling
dc.subject.otherExperimental section
dc.subject.otherPost treatment
dc.subject.otherPre-Treatment
dc.subject.otherSuspended solids
dc.subject.otherTotal dissolved solids
dc.subject.otherWastewater treatment
dc.titleEffect of White Charcoal on COD Reduction in Wastewater Treatment
dc.typeConference Paper
dspace.entity.typePublication
swu.datasource.scopushttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85025822300&doi=10.1088%2f1757-899X%2f216%2f1%2f012002&partnerID=40&md5=5400fd1ec05b9a98d8b92d4dc7dc2a27