Publication: Load cells application for developing weight-bearing detection via wireless connection
| dc.contributor.author | Jaysrichai T. | |
| dc.date.accessioned | 2021-04-05T03:21:40Z | |
| dc.date.available | 2021-04-05T03:21:40Z | |
| dc.date.issued | 2018 | |
| dc.date.issuedBE | 2561 | |
| dc.description.abstract | Objective: To focus on a device development for measuring the weight-bearing on feet while simultaneously reporting data on smartphone usage. Secondly, the output data from this device are tested for the accuracy. Methods: Researcher used eight pieces of 50 kg Body Load Cell Weighing Sensor Resistance strain Half-bridge Original (four pieces per foot), two pieces of HX711 amplifier, MCS-51 AT89 C51 microcontroller and HC-05-Bluetooth to develop the device. This device that is called the Wireless Weight-Shifting Detector (WWSD) is used to measure weight-bearing on feet by being attached to sandals. The output data are simultaneously reported on smartphone via line-graphs [load (kg) per sampling data] and numeric by FootpressV1 application. The device was tested using accurate measuring data with standard weights and calculated in percentage of accuracy (%). After that, WWSD was used to compare the weight-bearing measurement during standing with forceplate (AMTI; OR6-7 Platform). Results: The percentage of accuracy of WWSD was more than 97% and the error values from the measuring standard weights ranged under ±0.23 kg. The accuracy of measurement was more than 95% when compared with the force plate. Conclusion: WWSD can report simultaneously the weight-bearing on feet with rather accurate data on smartphone. It may be helpful in assisting physical therapists while training patients in clinic. © 2018 Tossaphon Jaysrichai. | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.citation | Open Biomedical Engineering Journal. Vol 12, No.1 (2018), p.101-107 | |
| dc.identifier.doi | 10.2174/1874120701812010101 | |
| dc.identifier.issn | 18741207 | |
| dc.identifier.other | 2-s2.0-85064919166 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14740/3752 | |
| dc.rights.holder | มหาวิทยาลัยศรีนครินทรวิโรฒ | |
| dc.subject.other | Accuracy | |
| dc.subject.other | Article | |
| dc.subject.other | Human | |
| dc.subject.other | Mathematical analysis | |
| dc.subject.other | Orthopedics | |
| dc.subject.other | Physiotherapist | |
| dc.subject.other | Physiotherapy | |
| dc.subject.other | Priority journal | |
| dc.subject.other | Scientist | |
| dc.subject.other | Voltage clamp technique | |
| dc.subject.other | Weight bearing | |
| dc.subject.other | Wireless communication | |
| dc.title | Load cells application for developing weight-bearing detection via wireless connection | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| swu.datasource.scopus | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85064919166&doi=10.2174%2f1874120701812010101&partnerID=40&md5=3004405aca4cd698002b058007993e6f |
