Publication:
Heat transfer and pressure drop in the horizontal double pipes with and without twisted tape insert

dc.contributor.authorNaphon P.
dc.date.accessioned2021-04-05T04:32:24Z
dc.date.available2021-04-05T04:32:24Z
dc.date.issued2006
dc.date.issuedBE2549
dc.description.abstractThe heat transfer characteristics and the pressure drop in the horizontal double pipes with twisted tape insert are investigated. Two test sections with different relative pitches are tested. The inner and outer diameters of the inner tube are 8.10 and 9.54 mm, respectively. The twisted tape is made from the aluminium strip with thickness of 1 mm and the length of 2000 mm. Cold and hot water are used as working fluids in shell side and tube side, respectively. The test runs are done at the cold and hot water mass flow rates ranging between 0.01 and 0.07 kg/s, and between 0.04 and 0.08 kg/s, respectively. The inlet cold and hot water temperatures are between 15 and 20 °C, and between 40 and 45 °C, respectively. The results obtained from the tube with twisted insert are compared with those without twisted tape. Non-isothermal correlations based on the data gathered during this work for predicting the heat transfer coefficient and friction factor of the horizontal pipe with twisted taped insert are proposed. The majority of the data falls within ±15%, ±10% of the proposed correlations for heat transfer coefficient and friction factor, respectively. © 2005 Elsevier Ltd. All rights reserved.
dc.format.mimetypeapplication/pdf
dc.identifier.citationInternational Communications in Heat and Mass Transfer. Vol 33, No.2 (2006), p.166-175
dc.identifier.doi10.1016/j.icheatmasstransfer.2005.09.007
dc.identifier.issn7351933
dc.identifier.other2-s2.0-32044435825
dc.identifier.urihttps://hdl.handle.net/20.500.14740/5939
dc.rights.holderมหาวิทยาลัยศรีนครินทรวิโรฒ
dc.subject.otherFlow of water
dc.subject.otherHeat transfer
dc.subject.otherIntake systems
dc.subject.otherPressure drop
dc.subject.otherReynolds number
dc.subject.otherTemperature control
dc.subject.otherTribology
dc.subject.otherTubes (components)
dc.subject.otherWater heaters
dc.subject.otherFriction factor
dc.subject.otherHeat transfer coefficient
dc.subject.otherHorizontal double pipes
dc.subject.otherInlet hot water temperatures
dc.subject.otherTwisted tape insert
dc.subject.otherWater mass flow
dc.subject.otherPipe
dc.subject.otherFlow of water
dc.subject.otherHeat transfer
dc.subject.otherIntake systems
dc.subject.otherPipe
dc.subject.otherPressure drop
dc.subject.otherReynolds number
dc.subject.otherTemperature control
dc.subject.otherTribology
dc.subject.otherTubes (components)
dc.subject.otherWater heaters
dc.titleHeat transfer and pressure drop in the horizontal double pipes with and without twisted tape insert
dc.typeArticle
dspace.entity.typePublication
swu.datasource.scopushttps://www.scopus.com/inward/record.uri?eid=2-s2.0-32044435825&doi=10.1016%2fj.icheatmasstransfer.2005.09.007&partnerID=40&md5=347e139d8f07c002a60553f566585ed0