dc.description.abstractElectrical Impedance Tomography (EIT) is an imaging technique which relies on the accuracy of boundary voltage measurement. In application to the head of EIT, the scalp voltage is very small and sensitive to noise and error. Electrode placement error is an error which is difficult to avoid in practice. Furthermore, the exact value of electrode contact impedance is difficult to know. In this study, the influence of electrode placement error and inaccurate electrode contact impedance were investigated by simulation. The result shows that the scalp voltage error due to the placement error was between 0.003 mV and 4.670 mV. Comparing to the scalp voltage response obtained from brain stimulation, which has been reported less than 90 μV, the most of the error values were much larger. The voltage errors due to inaccurate contact impedance were less than 1.2 μV which is very small and ignorable. This indicates the importance of the attachment procedure of electrodes that needs to be very careful. © 2019 IEEE.
dc.format.mimetypeapplication/pdf
dc.identifier.citationiEECON 2019 - 7th International Electrical Engineering Congress, Proceedings. (2019)
dc.identifier.doi10.1109/iEECON45304.2019.8939016
dc.identifier.other2-s2.0-85077969847
dc.identifier.urihttps://hdl.handle.net/20.500.14740/5419
dc.rights.holderScopus
dc.subject.otherElectric contacts
dc.subject.otherElectric impedance
dc.subject.otherElectric impedance measurement
dc.subject.otherElectric impedance tomography
dc.subject.otherElectrodes
dc.subject.otherBrain stimulation
dc.subject.otherContact impedance
dc.subject.otherElectrical impe dance tomography (EIT)
dc.subject.otherElectrical impedance tomography
dc.subject.otherElectrode contacts
dc.subject.otherElectrode placement
dc.subject.otherVoltage error
dc.subject.otherVoltage response
dc.subject.otherErrors
dc.titleInfluence of electrode placement error and contact impedance error to scalp voltage in electrical impedance tomography application
dc.typeConference Paper
dspace.entity.typePublication
swu.datasource.scopushttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85077969847&doi=10.1109%2fiEECON45304.2019.8939016&partnerID=40&md5=9eeeee7b42e35197e51ab8dd858f0ac1

Files