Publication:
Poly(ester-co-glycidyl methacrylate) for digital light processing in biomedical applications

dc.contributor.authorRisangud N.
dc.contributor.authorJiraborvornpongsa N.
dc.contributor.authorPasee S.
dc.contributor.authorKaewkong P.
dc.contributor.authorKunkit N.
dc.contributor.authorSungkhaphan P.
dc.contributor.authorJanvikul W.
dc.date.accessioned2022-03-10T13:17:46Z
dc.date.available2022-03-10T13:17:46Z
dc.date.issued2021
dc.date.issuedBE2564
dc.description.abstractMethacrylate-containing polyesters exploited for digital light processing (DLP) are generally prepared through ring-opening polymerization followed by photoactivation via methacrylation, which commonly requires the additional chemical and reaction workup. Herein, such a drawback is overcome by introducing a facile method of sequential addition of ester monomer and glycidyl methacrylate into the reaction. Two different hydroxyl beginning monomers, that is, ethylene glycol and glycerol, were utilized. The chemical structures and molecular weights of the resultant copolymers were analyzed using 1H-NMR and ATR-FTIR spectroscopy and size exclusion chromatography, respectively. The effects of the copolymer structures on the properties of both resins formulated with and without hydroxyapatite, for example, rheological behavior and printability, and DLP-printed specimens, for example, mechanical property and cytotoxicity, were assessed. By controlling the beginning monomer to monomer feeding ratio from 1:6 to 1:14, the Mn values of the resultant copolymers fell in the range of 1.7 to 2.5 kDa. The DLP-printed specimens possessed compressive moduli in the range of 10.20 ± 0.16 MPa and 18.65 ± 0.75 MPa. The cytotoxicity result suggested that the DLP-printed specimens were noncytotoxic to porcine chondrocytes. Altogether, these methacrylate-containing polyesters simply synthesized via a concise one-pot reaction revealed great potential for DLP printing resins in biomedical applications. © 2021 Wiley Periodicals LLC.
dc.format.mimetypeapplication/pdf
dc.identifier.citationJournal of Applied Polymer Science. Vol 138, No.42 (2021)
dc.identifier.doi10.1002/app.51391
dc.identifier.issn218995
dc.identifier.other2-s2.0-85110086369
dc.identifier.urihttps://hdl.handle.net/20.500.14740/8198
dc.language.isoeng
dc.rights.holderScopus
dc.subject.otherAcrylic monomers
dc.subject.otherEsters
dc.subject.otherEthylene
dc.subject.otherEthylene glycol
dc.subject.otherFourier transform infrared spectroscopy
dc.subject.otherFunctional polymers
dc.subject.otherHydroxyapatite
dc.subject.otherMedical applications
dc.subject.otherPolyester resins
dc.subject.otherPolyesters
dc.subject.otherSize exclusion chromatography
dc.subject.otherATR FT-IR spectroscopies
dc.subject.otherBiomedical applications
dc.subject.otherCompressive moduli
dc.subject.otherCopolymer structure
dc.subject.otherDigital light processing
dc.subject.otherGlycidyl methacrylate
dc.subject.otherRheological behaviors
dc.subject.otherSequential addition
dc.subject.otherRing opening polymerization
dc.titlePoly(ester-co-glycidyl methacrylate) for digital light processing in biomedical applications
dc.typeArticle
dspace.entity.typePublication
swu.datasource.scopushttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85110086369&doi=10.1002%2fapp.51391&partnerID=40&md5=27549efa5a3d4fc5a7fec27220597c32

Files