Publication: Diagnostic performance of anterior segment optical coherence tomography in detecting plateau iris
| dc.contributor.author | Wanichwecharungruang B. | |
| dc.contributor.author | Pattanapongpaiboon W. | |
| dc.contributor.author | Kongsomboon K. | |
| dc.contributor.author | Parivisutt N. | |
| dc.contributor.author | Annopawong K. | |
| dc.contributor.author | Seresirikachorn K. | |
| dc.date.accessioned | 2022-12-14T03:16:54Z | |
| dc.date.available | 2022-12-14T03:16:54Z | |
| dc.date.issued | 2022 | |
| dc.date.issuedBE | 2565 | |
| dc.description.abstract | Objective To evaluate the diagnostic performance of manual grading of anterior segment optical coherence tomography (AS-OCT) in detection of plateau iris configuration (PIC) based on the presence of standardised ultrasound biomicroscopy (UBM) criteria in at least two quadrants; namely, clinical diagnosis of PIC (DxPIC). Methods and analysis In this cross-sectional study, paired AS-OCT and UBM images were evaluated by three glaucoma specialists. AS-OCT was classified into two mechanisms, PIC versus non-PIC, of primary angle closure disease (PACD) and AS-OCT-PIC diagnostic performance was tested with DxPIC. Results One hundred and seventy-nine eyes of 142 patients were enrolled for analysis, and DxPIC was found in 85 eyes (47.49%). Intraobserver agreement rates of AS-OCT classification by the graders were 0.77, 0.701 and 0.742 (all p<0.001), and interobserver agreement rates, between a senior glaucoma specialist and the other two glaucoma specialists, were 0.68 and 0.702 (all p<0.001). Plateau iris was classified in AS-OCT images by the three graders, rated 32.96%-39.1% and 24.58%-34.08% in the horizontal and vertical axes, respectively. Diagnostic performance was analysed, yielding sensitivity ranging from 56.47% to 77.78%, and specificity of 48.94% to 64.29%. We applied disease prevalence of 30%, revealing positive predictive values varying from 32.16% to 44.44%, and negative predictive values of 72.4% to 85.71%. Accuracy ranged from 51.2% to 65%. Agreement between the two devices was fair, kappa range 0.31-0.351. Conclusion Performance of manual grading of AS-OCT in detection of DxPIC was relatively poor; therefore, unadjusted AS-OCT does not appear to be good for manual PIC screening in PACD patients and cannot serve as a substitute for UBM in PIC detection. © Author(s) (or their employer(s)) 2022. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.citation | Pharmaceutics. Vol 14, No.5 (2022), p.- | |
| dc.identifier.doi | 10.1136/bmjophth-2021-000931 | |
| dc.identifier.issn | 23973269 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14740/9127 | |
| dc.language.iso | eng | |
| dc.publisher | BMJ Publishing Group | |
| dc.rights.holder | Scopus | |
| dc.subject.other | Angle | |
| dc.subject.other | Ciliary body | |
| dc.subject.other | Diagnostic tests/Investigation | |
| dc.subject.other | Glaucoma | |
| dc.subject.other | Imaging | |
| dc.title | Diagnostic performance of anterior segment optical coherence tomography in detecting plateau iris | |