Publication:
Constrained modeling for image reconstruction in the application of Electrical Impedance Tomography to the head

dc.contributor.authorOuypornkochagorn T.
dc.date.accessioned2021-04-05T03:22:13Z
dc.date.available2021-04-05T03:22:13Z
dc.date.issued2017
dc.date.issuedBE2560
dc.description.abstractElectrical Impedance Tomography (EIT) is an alternative way to image brain functions, in the form of conductivity distribution image, by using the boundary voltage information while a small current is injected. In head applications, due to the lack of accurate head models and the high-degree nonlinearity, the image reconstruction tends to fail. Recently, a nonlinear difference imaging approach has been proposed to mitigate modeling error. This approach, however, is based on unconstrained modeling that allows tissue conductivity values to be unrealistically negative. Consequently, substantial image artifacts are possibly conducted. In this work, two methods of constrained modeling were demonstrated they are able to substantially reduce artifacts and improve localization performance. New images of conductivity distribution of the mapped constraint domains, derived from the use of constrained modeling, are also exhibited here. The simulation result shows that the new images achieve better localization performance than those of using unconstrained modeling. © 2017 IEEE.
dc.format.mimetypeapplication/pdf
dc.identifier.citationProceedings - International Symposium on Biomedical Imaging. (2017), p.548-551
dc.identifier.doi10.1109/ISBI.2017.7950580
dc.identifier.issn19457928
dc.identifier.other2-s2.0-85023190801
dc.identifier.urihttps://hdl.handle.net/20.500.14740/4142
dc.rights.holderมหาวิทยาลัยศรีนครินทรวิโรฒ
dc.subject.otherElectric impedance
dc.subject.otherElectric impedance measurement
dc.subject.otherElectric impedance tomography
dc.subject.otherImage processing
dc.subject.otherMedical imaging
dc.subject.otherTomography
dc.subject.otherConductivity distributions
dc.subject.otherConstrained models
dc.subject.otherDifference imaging
dc.subject.otherElectrical impe dance tomography (EIT)
dc.subject.otherElectrical impedance tomography
dc.subject.otherLocalization performance
dc.subject.otherModel errors
dc.subject.otherTissue conductivity
dc.subject.otherImage reconstruction
dc.titleConstrained modeling for image reconstruction in the application of Electrical Impedance Tomography to the head
dc.typeConference Paper
dspace.entity.typePublication
swu.datasource.scopushttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85023190801&doi=10.1109%2fISBI.2017.7950580&partnerID=40&md5=5c02834c42d12041f86aefc5a52ce29d

Files