dc.description.abstractHere, we report a simple visual colorimetric sensing system based on the self-assembly of gold nanorods (AuNRs) and graphene oxide (GO) for heparin detection using a polycationic polymer, polydiallyldimethylammonium chloride (PDADMAC), as a molecular probe. Within the system, the polycationic PDADMAC polymer binds tightly with GO, preventing the absorption of AuNRs on the GO surface. Consequently, the AuNRs are well dispersed in the system and maintain their native red color. In the presence of heparin, PDADMAC forms a stable complex with heparin, rendering the AuNRs self-assembled on the GO surface. As a result, this leads to AuNR aggregation and a change in color from red to purple due to a decrease in localized surface plasmon resonance (LSPR). The change in the absorption maxima of the AuNRs upon the presence of heparin was recorded. Under the optimized conditions, heparin can be detected in the range of 20-140 ng mL-1 (R2 = 0.9524). Using 3σ/s, where σ is the standard deviation of the blank and s is the slope of the linear graph, heparin can be detected at as low as 10.4 nanograms with a sample volume of 100 μL. The system also demonstrates selectivity of heparin detection against other potential interferences including ions and proteins. © 2019 The Royal Society of Chemistry.
dc.format.mimetypeapplication/pdf
dc.identifier.citationAnalytical Methods. Vol 11, No.10 (2019), p.1387-1392
dc.identifier.doi10.1039/c8ay02129e
dc.identifier.issn17599660
dc.identifier.other2-s2.0-85062777838
dc.identifier.urihttps://hdl.handle.net/20.500.14740/5408
dc.rights.holderScopus
dc.subject.otherChlorine compounds
dc.subject.otherColor
dc.subject.otherColorimetry
dc.subject.otherGold compounds
dc.subject.otherGraphene
dc.subject.otherNanorods
dc.subject.otherPlasmons
dc.subject.otherPolymers
dc.subject.otherProbes
dc.subject.otherSelf assembly
dc.subject.otherSurface plasmon resonance
dc.subject.otherColorimetric sensing
dc.subject.otherGold nanorods (AuNRs)
dc.subject.otherLocalized surface plasmon resonance
dc.subject.otherOptimized conditions
dc.subject.otherPolycationic polymers
dc.subject.otherPolydiallyldimethyl ammonium chloride
dc.subject.otherPotential interferences
dc.subject.otherStandard deviation
dc.subject.otherPolysaccharides
dc.titleVisual colorimetric sensing system based on the self-assembly of gold nanorods and graphene oxide for heparin detection using a polycationic polymer as a molecular probe
dc.typeArticle
dspace.entity.typePublication
swu.datasource.scopushttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85062777838&doi=10.1039%2fc8ay02129e&partnerID=40&md5=0e3ca7760e2424d12238b5ea991f249c

Files