Publication:
Reliability of the radiographic views in supine position for evaluation of displaced midshaft clavicle fracture length

dc.contributor.authorKongmalai P.
dc.contributor.authorChiaprasert P.
dc.contributor.authorRungsinaporn V.
dc.date.accessioned2021-04-05T03:01:31Z
dc.date.available2021-04-05T03:01:31Z
dc.date.issued2020
dc.date.issuedBE2563
dc.description.abstractPurpose: To analyze the agreement of the displaced midshaft clavicle fracture length measurement between each of the supine radiographic position (chest anteroposterior (AP), both clavicle AP, and 20° cephalic tilt clavicle AP view) and computed tomography (CT) scan of the clavicle. Furthermore, the inter- and intraobserver reliability of each radiographic position was analyzed. Methods: Prospective cross-sectional study was performed with patients diagnosed with displaced midshaft clavicle fracture treated conservatively. Three views of radiographs and CT scan of clavicle were obtained in supine position after informed consent. The measurement of fractured clavicle length was done by three observers at the time and after 4 weeks interval. Results: Thirty-three patients (25 males and 8 females), with a mean age of 45, were recruited. The agreement between each of the radiographic measurement and CT scan was good. The interobserver reliability was moderate to good for radiographic measurement. The highest intraclass correlation coefficient (ICC) of 0.80–0.81 was shown between the 20° cephalic tilt and the CT scan, followed by the both clavicle AP (0.75–0.77) and the chest AP (0.69–0.75), respectively. There was an excellent intraobserver reliability for all of the radiographic measurement with the ICC 0.92–0.99. Conclusion: The supine radiographs could be a useful option to measure the displaced midshaft clavicle fracture length. The recommended view was the 20° cephalic tilt clavicle AP view in supine position to best evaluate the fractured clavicle length. © The Author(s) 2020.
dc.format.mimetypeapplication/pdf
dc.identifier.citationJournal of Orthopaedic Surgery. Vol 28, No.3 (2020)
dc.identifier.doi10.1177/2309499020952295
dc.identifier.issn10225536
dc.identifier.other2-s2.0-85090787643
dc.identifier.urihttps://hdl.handle.net/20.500.14740/4573
dc.rights.holderScopus
dc.subject.otherAdult
dc.subject.otherAge
dc.subject.otherAged
dc.subject.otherArticle
dc.subject.otherClavicle fracture
dc.subject.otherClinical article
dc.subject.otherComputer assisted tomography
dc.subject.otherCross-sectional study
dc.subject.otherDisplaced midshaft clavicle fracture length measurement
dc.subject.otherFemale
dc.subject.otherFracture dislocation
dc.subject.otherGender
dc.subject.otherHuman
dc.subject.otherInformed consent
dc.subject.otherInterrater reliability
dc.subject.otherIntrarater reliability
dc.subject.otherMale
dc.subject.otherProspective study
dc.subject.otherReliability
dc.subject.otherSupine position
dc.subject.otherThorax radiography
dc.subject.otherVery elderly
dc.titleReliability of the radiographic views in supine position for evaluation of displaced midshaft clavicle fracture length
dc.typeArticle
dspace.entity.typePublication
swu.datasource.scopushttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85090787643&doi=10.1177%2f2309499020952295&partnerID=40&md5=d8e4bcdb6357277092dc4df815a1c272

Files