Publication:
Highly sensitive determination of trace copper in food by adsorptive stripping voltammetry in the presence of 1,10-phenanthroline

dc.contributor.authorChaiyo S.
dc.contributor.authorChailapakul O.
dc.contributor.authorSakai T.
dc.contributor.authorTeshima N.
dc.contributor.authorSiangproh W.
dc.date.accessioned2021-04-05T03:33:22Z
dc.date.available2021-04-05T03:33:22Z
dc.date.issued2013
dc.date.issuedBE2556
dc.description.abstractA highly sensitive, rapid, simple and selective adsorptive stripping assay for the determination of trace copper(II) is proposed. The methodology is based on the adsorptive accumulation of copper(II)-1,10-phenanthroline complexes onto a glassy carbon electrode, followed by oxidation of the adsorbed species by voltammetric scanning using square-wave voltammetry. The influences of experimental variables on the sensitivity of the proposed method, such as the effects of pH, ligand concentration, accumulation time, accumulation potential and interferences, were investigated. Under optimal conditions, the proposed method showed linearity from 0.1 ng mL-1 to 50 ng mL-1. The 3 S/N detection limits were 0.0185 ng mL-1, and the relative standard deviations (n=10) were 0.09-4.71% for intra-day and 0.05-7.14% for inter-day analyses, respectively. The application of the proposed method to the direct analysis of food samples yielded results that agreed with those obtained from including inductively coupled plasma-optical emission spectrometry (ICP-OES) assays according to a paired t-test. The results are a step toward the development of an alternative and reliable analytical method for food research, which requires the direct determination of copper. © 2013 Published by Elsevier B.V.
dc.format.mimetypeapplication/pdf
dc.identifier.citationTalanta. Vol 108, No. (2013), p.1-6
dc.identifier.doi10.1016/j.talanta.2013.02.031
dc.identifier.issn399140
dc.identifier.other2-s2.0-84875135495
dc.identifier.urihttps://hdl.handle.net/20.500.14740/6788
dc.rights.holderมหาวิทยาลัยศรีนครินทรวิโรฒ
dc.subject.other1,10-phenanthroline
dc.subject.otherAdsorptive stripping voltammetry
dc.subject.otherCopper
dc.subject.otherFood samples
dc.subject.otherTrace determination of copper
dc.titleHighly sensitive determination of trace copper in food by adsorptive stripping voltammetry in the presence of 1,10-phenanthroline
dc.typeArticle
dspace.entity.typePublication
swu.datasource.scopushttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84875135495&doi=10.1016%2fj.talanta.2013.02.031&partnerID=40&md5=a852cdff312e086513d6325ad4681652

Files