Publication:
Rapid separation and highly sensitive detection methodology for sulfonamides in shrimp using a monolithic column coupled with BDD amperometric detection

dc.contributor.authorSangjarusvichai H.
dc.contributor.authorDungchai W.
dc.contributor.authorSiangproh W.
dc.contributor.authorChailapakul O.
dc.date.accessioned2021-04-05T04:32:10Z
dc.date.available2021-04-05T04:32:10Z
dc.date.issued2009
dc.date.issuedBE2552
dc.description.abstractIn this report, we aimed to extend our previous efforts toward the evaluation of sulfonamides (SAs) with a boron-doped diamond (BDD) electrode. We improved this method by reducing the analysis time using a monolithic column coupled with amperometric detection to determine seven sulfonamides (sulfaguanidine, sulfadiazine, sulfamethazine, sulfamonomethoxine, sulfamethoxazole, sulfadimethoxine and sulfaquinoxaline). Because of its rapid separation, low back-pressure and high separation efficiency compared to a particle-packed column, a monolithic column (100 mm × 4.6 mm) was used for sulfonamide separation. Chromatographic separation was performed in less than 8 min. The analysis was carried out using phosphate buffer (0.1 M, pH 3): acetonitrile: methanol in a ratio of 80:15:5 (v/v/v) as the mobile phase with a flow rate of 1.5 mL min-1. The optimal detection potential using hydrodynamic voltammetry was found to be 1.2 V versus Ag/AgCl. The method was applied to determine seven sulfonamides in shrimp after sample preparation by solid-phase extraction. The recoveries of the sulfonamides in spiked shrimp samples at 1.5, 5 and 10 μg g-1 were in the range of 81.7 to 97.5% with a relative standard deviation (R.S.D.) between 1.0 and 4.6%. Our methodology produced results that were highly correlated with HPLC-MS data. Therefore, we propose a method that can be used for the rapid, selective and sensitive evaluation of sulfonamides in contaminated food. © 2009 Elsevier B.V. All rights reserved.
dc.format.mimetypeapplication/pdf
dc.identifier.citationTalanta. Vol 79, No.4 (2009), p.1036-1041
dc.identifier.doi10.1016/j.talanta.2009.02.026
dc.identifier.issn399140
dc.identifier.other2-s2.0-67650456893
dc.identifier.urihttps://hdl.handle.net/20.500.14740/4570
dc.rights.holderScopus
dc.subject.otherAmides
dc.subject.otherBoolean functions
dc.subject.otherDrug products
dc.subject.otherElectrodes
dc.subject.otherHigh performance liquid chromatography
dc.subject.otherPhase separation
dc.subject.otherShellfish
dc.subject.otherAmperometric detection
dc.subject.otherBoron doped diamond electrodes
dc.subject.otherChromatographic separations
dc.subject.otherHigh separation efficiency
dc.subject.otherHighly sensitive detections
dc.subject.otherMonolithic columns
dc.subject.otherRelative standard deviation (R.S.D.)
dc.subject.otherSulfonamides
dc.subject.otherSulfur compounds
dc.titleRapid separation and highly sensitive detection methodology for sulfonamides in shrimp using a monolithic column coupled with BDD amperometric detection
dc.typeArticle
dspace.entity.typePublication
swu.datasource.scopushttps://www.scopus.com/inward/record.uri?eid=2-s2.0-67650456893&doi=10.1016%2fj.talanta.2009.02.026&partnerID=40&md5=eb675944a873a2770a4ef052840840d7

Files