Publication:
Transient thermal performance of constant fill ratio vapor chamber with different coolants

dc.contributor.authorWiriyasart S.
dc.contributor.authorNaphon P.
dc.date.accessioned2022-03-10T13:17:12Z
dc.date.available2022-03-10T13:17:12Z
dc.date.issued2021
dc.date.issuedBE2564
dc.description.abstractIn this study, a constant fill ratio vapor chamber using water and ferrofluid as the coolants on the thermal performance and thermal optimization to provide the cooling range are presented. The liquid flow rate of the condenser side ranges from 0.029−0.099 kg/s, the input power of 100−300 W, heat source size of 30 mm × 30 mm, and the water and ferrofluid with φ=0 %, φ=0.005 % and φ=0.05 % as coolants are investigated. The results indicate that the minimum thermal resistance of a traditional vapor chamber of 0.126oC/W at mo = 0.075 kg/s and vapor chamber with a mini channel of 0.077oC/W at mo = 0.049 kg/s at φ=0.005 % are obtained. The vapor chamber with and without mini channel at a certain fill ratio of 26 % and 33 %, the heat source size of 30 mm × 30 mm, and the mass flow rate of ≥ 0.042 kg/s are withstanding the heat load range from 100–200 W. However, to achieve the high heat load range from 100–300 W, the vapor chamber with mini channel using the Fe3O4 ferrofluid φ=0.005 % is covering the entire cooling range and is recommended in electronic cooling applications. © 2021 The Japan Society of Mechanical Engineers.
dc.format.mimetypeapplication/pdf
dc.identifier.citationJournal of Thermal Science and Technology. Vol 16, No.2 (2021)
dc.identifier.doi10.1299/jtst.2021jtst0028
dc.identifier.issn18805566
dc.identifier.other2-s2.0-85107308894
dc.identifier.urihttps://hdl.handle.net/20.500.14740/8046
dc.language.isoeng
dc.rights.holderScopus
dc.subject.otherCoolants
dc.subject.otherIron oxides
dc.subject.otherMagnetite
dc.subject.otherThermal load
dc.subject.otherCooling applications
dc.subject.otherHigh heat load
dc.subject.otherLiquid flow rates
dc.subject.otherMass flow rate
dc.subject.otherMini channels
dc.subject.otherThermal optimization
dc.subject.otherThermal Performance
dc.subject.otherVapor chamber
dc.subject.otherElectronic cooling
dc.titleTransient thermal performance of constant fill ratio vapor chamber with different coolants