Publication:
Hyperdynamic circulation in portal hypertension: A comparative model of arterio-venous fistula

dc.contributor.authorWattanasirichaigoon S.
dc.contributor.authorGordon F.D.
dc.contributor.authorResnick R.H.
dc.date.accessioned2021-04-05T04:33:28Z
dc.date.available2021-04-05T04:33:28Z
dc.date.issued2000
dc.date.issuedBE2543
dc.description.abstractComplications of portal hypertension remain perplexing physiologic phenomena in the understanding of shunt hemodynamics with multiple theories. Hyperdynamic circulation was also found in sepsis, chronic anemia and arterio-venous (A-V) fistula which relate to an increase in nitric oxide. We hypothesize that portosystemic collaterals may mimic an A-V fistula in which the high-pressure portal blood connects with the lower pressure systemic venous circulation. Although these collaterals decompress the portal circulation, a number of secondary hemodynamic phenomena occur which increase portal blood flow and tend to counteract the portal hypotensive effect of the portosystemic shunt. The consequent increases in cardiac output and portal blood flow perfuse the compromised liver. As portal blood flow increases, collateral flow increases and is nearly totally shunted in the systemic circulation. This shunt may eventually introduce a vicious cycle of hyperdynamic circulation into a compromised host. Ultimately, high-output cardiac failure occurs, leading to cirrhotic cardiomyopathy. (C) 2000 Harcourt Publishers Ltd.
dc.format.mimetypeapplication/pdf
dc.identifier.citationMedical Hypotheses. Vol 55, No.1 (2000), p.77-87
dc.identifier.doi10.1054/mehy.1999.1034
dc.identifier.issn3069877
dc.identifier.other2-s2.0-0033868262
dc.identifier.urihttps://hdl.handle.net/20.500.14740/7068
dc.rights.holderScopus
dc.subject.otherBeta adrenergic receptor blocking agent
dc.subject.otherNitric oxide synthase inhibitor
dc.subject.otherAnimal experiment
dc.subject.otherAnimal model
dc.subject.otherArticle
dc.subject.otherCardiomyopathy
dc.subject.otherControlled study
dc.subject.otherHeart output
dc.subject.otherHemodynamics
dc.subject.otherNonhuman
dc.subject.otherPortal hypertension
dc.subject.otherPortal vein blood flow
dc.subject.otherPriority journal
dc.subject.otherRat
dc.subject.otherAnimalia
dc.subject.otherFistula
dc.titleHyperdynamic circulation in portal hypertension: A comparative model of arterio-venous fistula
dc.typeArticle
dspace.entity.typePublication
swu.datasource.scopushttps://www.scopus.com/inward/record.uri?eid=2-s2.0-0033868262&doi=10.1054%2fmehy.1999.1034&partnerID=40&md5=0e05cadc9fadf30096648327b36398f0

Files