Publication: Enzyme-free impedimetric biosensor-based molecularly imprinted polymer for selective determination of L-hydroxyproline
0
0
Issued Date
2021
Resource Type
Language
eng
File Type
application/pdf
ISSN
9565663
Other identifier(s)
2-s2.0-85107970643
Rights Holder(s)
Scopus
Bibliographic Citation
Biosensors and Bioelectronics. Vol 191, No. (2021)
Suggested Citation
Jesadabundit W., Jampasa S., Patarakul K., Siangproh W., Chailapakul O. Enzyme-free impedimetric biosensor-based molecularly imprinted polymer for selective determination of L-hydroxyproline. Biosensors and Bioelectronics. Vol 191, No. (2021). doi:10.1016/j.bios.2021.113387 Retrieved from: https://hdl.handle.net/20.500.14740/8151
Abstract
This study first reported enzyme-free impedimetric biosensor-based molecularly imprinted polymers for selective and sensitive determination of L-hydroxyproline (L-hyp), a biomarker for the early diagnosis of bone diseases. In recent study, utilizing a single 3-aminophenylboronic acid (3-APBA) to create imprinted surfaces could result in a strong interaction and difficulty in removal of a template molecule. Hence, a mixture of monomer solution containing 3-APBA and o-phenylenediamine (OPD) in the presence of the L-hyp molecule was co-electropolymerized onto the screen-printed electrode using cyclic voltammetry (CV) to eradicate this mentioned limitation. The detection principle of this sensor is relied on alteration of mediator's charge transfer resistance (Rct) that could be obstructed by L-hyp occupied in imprinted surface. The successfully fabricated biosensor was explored by scanning electron microscopy (SEM), Fourier-transform infrared spectroscopy (FTIR), and confocal scanning microscopy. Furthermore, the effect of polymer composition on the Rct response was systematically investigated. The result exhibited that the mixture of monomers could provide the highest change of Rct due to high selectivity from esterification of 3-APBA and from hydrogen bond of OPD surrounding the template. The sensor showed a significant increase in Rct in the presence of L-hyp, whereas no observable resistance change was detected in the absence thereof. The calibration curve was obtained in the range from 0.4 to 25 μg mL−1 with limits of detection (3SDblank/Slope) and quantification (10SDblank/Slope) of 0.13 and 0.42 μg mL−1, respectively. This biosensor exhibited high selectivity and sensitivity and was successfully applied to determine L-hyp in human serum samples with satisfactory results. © 2021 Elsevier B.V.
Subject(s)
Biosensors
Bone
Charge transfer
Cyclic voltammetry
Diagnosis
Enzymes
Fourier transform infrared spectroscopy
Hydrogen bonds
Mixtures
Molecules
Monomers
Scanning electron microscopy
3-Aminophenylboronic acid
Bone disease
Electrochemical-impedance spectroscopies
High selectivity
Impedimetric biosensors
L hydroxyprolines
Molecularly Imprinted Polymer
Nonenzymatic sensor
O-Phenylenediamine
Selective determination
Electrochemical impedance spectroscopy
1,2 phenylenediamine
Hydroxyproline
Polymer
Hydroxyproline
Molecularly imprinted polymer
Article
Bone disease
Calibration
Confocal laser scanning microscopy
Cyclic voltammetry
Esterification
Fourier transform infrared spectroscopy
Human
Hydrogen bond
Impedance spectroscopy
Limit of detection
Molecular imprinting
Normal human
Scanning electron microscopy
Electrochemical analysis
Electrode
Genetic procedures
Biosensing Techniques
Electrochemical Techniques
Electrodes
Humans
Hydroxyproline
Limit of Detection
Molecular Imprinting
Molecularly Imprinted Polymers
Bone
Charge transfer
Cyclic voltammetry
Diagnosis
Enzymes
Fourier transform infrared spectroscopy
Hydrogen bonds
Mixtures
Molecules
Monomers
Scanning electron microscopy
3-Aminophenylboronic acid
Bone disease
Electrochemical-impedance spectroscopies
High selectivity
Impedimetric biosensors
L hydroxyprolines
Molecularly Imprinted Polymer
Nonenzymatic sensor
O-Phenylenediamine
Selective determination
Electrochemical impedance spectroscopy
1,2 phenylenediamine
Hydroxyproline
Polymer
Hydroxyproline
Molecularly imprinted polymer
Article
Bone disease
Calibration
Confocal laser scanning microscopy
Cyclic voltammetry
Esterification
Fourier transform infrared spectroscopy
Human
Hydrogen bond
Impedance spectroscopy
Limit of detection
Molecular imprinting
Normal human
Scanning electron microscopy
Electrochemical analysis
Electrode
Genetic procedures
Biosensing Techniques
Electrochemical Techniques
Electrodes
Humans
Hydroxyproline
Limit of Detection
Molecular Imprinting
Molecularly Imprinted Polymers