Publication:
Energy savings analysis and harmonics reduction for the electronic ballast of T5 fluorescent lamp in a building's lighting system

dc.contributor.authorChiradeja P.
dc.contributor.authorNgaopitakkul A.
dc.contributor.authorJettanasen C.
dc.date.accessioned2021-04-05T03:25:44Z
dc.date.available2021-04-05T03:25:44Z
dc.date.issued2015
dc.date.issuedBE2558
dc.description.abstractLighting is one of the major energy end uses, which accounts for approximately 20-30% of electricity consumption in buildings. In fact, the fluorescent lamp is the most employed lamp in a lighting system for both inside and outside the building. The ballast is one of the major components of fluorescent lamps; it exists commercially as an electromagnetic ballast, a low loss ballast and an electronic ballast. To reduce energy consumption in a lighting system, the electronic ballast has already been introduced for profit in terms of its peak demand reduction and energy conservation in the building. However, when the electronic ballast functions, harmonics will be generated. Hence, this paper investigates energy savings and the generation of harmonics when using a fluorescent T5 lamp with electronic ballast in a building. The efficiency indices in terms of illumination, energy savings, and harmonics are also evaluated and compared with the fluorescent T8 lamp operating with a low watt loss electromagnetic ballast, which is also widely used. The obtained results are useful for the design and decision to install a fluorescent T5 lamp with electronic ballast in building lighting system to conserve energy and/or reduce energy consumption for the future of the country. © 2015 Published by Elsevier B.V.
dc.format.mimetypeapplication/pdf
dc.identifier.citationEnergy and Buildings. Vol 97, (2015), p.107-117
dc.identifier.doi10.1016/j.enbuild.2015.03.042
dc.identifier.issn3787788
dc.identifier.other2-s2.0-84927718027
dc.identifier.urihttps://hdl.handle.net/20.500.14740/6129
dc.rights.holderScopus
dc.subject.otherBallasts (lamp)
dc.subject.otherBuildings
dc.subject.otherEnergy utilization
dc.subject.otherFluorescence
dc.subject.otherFluorescent lamps
dc.subject.otherHarmonic analysis
dc.subject.otherHistoric preservation
dc.subject.otherLighting
dc.subject.otherLighting fixtures
dc.subject.otherElectricity-consumption
dc.subject.otherElectromagnetic ballasts
dc.subject.otherElectronic ballasts
dc.subject.otherGeneration of harmonics
dc.subject.otherHarmonics
dc.subject.otherHarmonics reduction
dc.subject.otherLighting systems
dc.subject.otherReduce energy consumption
dc.subject.otherEnergy conservation
dc.titleEnergy savings analysis and harmonics reduction for the electronic ballast of T5 fluorescent lamp in a building's lighting system
dc.typeArticle
dspace.entity.typePublication
swu.datasource.scopushttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84927718027&doi=10.1016%2fj.enbuild.2015.03.042&partnerID=40&md5=a295f1fdc9f747c1726b9c422256b594

Files