dc.description.abstractObjective: This study compared the aerosol and splatter diameter and count numbers produced by a dental mouth prop with a suction holder device and a saliva ejector during ultrasonic scaling in a clinical setting. Methodology: Fluorescein dye was placed in the dental equipment irrigation reservoirs with a mannequin, and an ultrasonic scaler was employed. The procedures were performed three times per device. The upper and bottom board papers were placed on the laboratory platform. All processes used an ultrasonic scaler to generate aerosol and splatter. A dental mouth prop with a suction holder and a saliva ejector were also tested. Photographic analysis was used to examine the fluorescein samples, followed by image processing in Python and assessment of the diameter and count number. For device comparison, statistics were used with an independent t-test. Result: When using the dental mouth prop with a suction holder, the scaler produced aerosol particles that were maintained on the upper board paper (mean ± SD: 1080 ± 662 µm) compared to on the bottom board paper (1230 ± 1020 µm). When the saliva ejector was used, it was found that the diameter of the aerosol on the upper board paper was 900 ± 580 µm, and the diameter on the bottom board paper was 1000 ± 756 µm. Conclusion: There was a significant difference in the aerosol and splatter particle diameter and count number between the dental mouth prop with a suction holder and saliva ejector (p < 0.05). Furthermore, the results revealed that there was a statistically significant difference between the two groups on the upper and bottom board papers. © 2022 by the authors.
dc.format.mimetypeapplication/pdf
dc.identifier.citationScientific Reports. Vol 12, No.1 (2022)
dc.identifier.doi10.3390/dj10080142
dc.identifier.issn23046767
dc.identifier.urihttps://hdl.handle.net/20.500.14740/10371
dc.language.isoeng
dc.publisherMDPI
dc.rights.holderมหาวิทยาลัยศรีนครินทรวิโรฒ
dc.subject.otherAerosols
dc.subject.otherAlgorithms
dc.subject.otherDental equipment
dc.subject.otherDental scaling
dc.subject.otherSuction
dc.titleComparative Dissemination of Aerosol and Splatter Using Suction Device during Ultrasonic Scaling: A Pilot Study
dc.typeArticle
dspace.entity.typePublication
swu.datasource.scopushttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85136641955&doi=10.3390%2fdj10080142&partnerID=40&md5=b0276dad12522be53834bcbc3f0eb737

Files