Publication:
Five Variable Number of Tandem Repeats Loci (D17S5, APOB, TPO Intron 10, IL-1α Intron 6, and CIAS1) in Thais and Application in the Prenatal Diagnostic Laboratory

dc.contributor.authorSingsanan S.
dc.contributor.authorYamsri S.
dc.contributor.authorPangjit K.
dc.contributor.authorSaenwang P.
dc.contributor.authorKarnpean R.
dc.contributor.authorFucharoen S.
dc.date.accessioned2022-12-14T03:16:58Z
dc.date.available2022-12-14T03:16:58Z
dc.date.issued2022
dc.date.issuedBE2565
dc.description.abstractBackground: Prenatal diagnosis of genetic disease requires DNA analysis of fetal tissue of a responsible gene. Accurate diagnosis is useful for the appropriate management of pregnancy. However, maternal contamination of fetal specimens poses a high preanalytical risk of prenatal misdiagnosis. We have examined five variable number of tandem repeat (VNTR) polymorphisms for use in monitoring potential maternal contamination. Materials and Methods: A study was conducted to examine the heterozygosities of five VNTR loci including, D17S5, APOB, TPO intron 10, IL-1α intron 6, and CIAS1 in 200 unrelated Thai subjects and applied to the monitoring of maternal contamination in 22 families at risk of having fetuses with severe thalassemia. Results: The heterozygosities of D17S5, APOB, TPO intron 10, IL-1α intron 6, and CIAS1 VNTRs were 59.5, 19.5, 66.0, 35.5, and 42.0%, respectively. Therefore, the TPO intron 10 and D17S5 loci were chosen for prenatal diagnosis of thalassemia in 22 families. Analyses of these VNTRs demonstrated an increase of informative data from 59.1% provided by the routine D1S80 VNTR analysis to 90.9%. Conclusions: The VNTR diagnostic procedure described above is simple, cost-effective, rapid, and does not require the use of sophisticated instruments; it should prove useful in the prenatal diagnosis of thalassemia. © 2022, Mary Ann Liebert, Inc., publishers 2022.
dc.format.mimetypeapplication/pdf
dc.identifier.citationEurasian Journal of Educational Research. Vol 2022, No.98 (2022), p.131-146
dc.identifier.doi10.1089/gtmb.2022.0010
dc.identifier.issn19450265
dc.identifier.urihttps://hdl.handle.net/20.500.14740/9256
dc.language.isoeng
dc.publisherMary Ann Liebert Inc.
dc.rights.holderScopus
dc.subject.otherHeterozygosity
dc.subject.otherMaternal cell contamination
dc.subject.otherPrenatal diagnosis
dc.subject.otherVNTR
dc.titleFive Variable Number of Tandem Repeats Loci (D17S5, APOB, TPO Intron 10, IL-1α Intron 6, and CIAS1) in Thais and Application in the Prenatal Diagnostic Laboratory
dc.typeArticle
dspace.entity.typePublication
swu.datasource.scopushttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85133144157&doi=10.1089%2fgtmb.2022.0010&partnerID=40&md5=1e775be253cc4ecc83e0e220df285acb

Files