Publication:
Accuracy of VITROS alcohol analysis for post-mortem specimens

dc.contributor.authorLekskulchai V.
dc.date.accessioned2021-04-05T03:32:31Z
dc.date.available2021-04-05T03:32:31Z
dc.date.issued2014
dc.date.issuedBE2557
dc.description.abstractIn forensic cases, blood alcohol is routinely requested. Although the standard method for alcohol analysis is the gas chromatographic technique, the instrument is not available in some hospital laboratories. As a result, there is an attempt to use an automatic alcohol analyzer for preliminary testing. However, a barrier to application is the putrefactive changes of post-mortem specimens that might interfere with the analysis and cause false positive results. This study aims to determine the accuracy of an automatic VITROS alcohol analysis for post-mortem specimens. Blood and urine samples were modified to putrefactive appearances and analyzed for ethanol by VITROS. The measured amounts were compared with the added ethanol amounts. The results indicated that samples with fresh hemolysis and putrefactive volatile substances gave false high ethanol results. Plasma with a high glucose content in the presence of Escherichia coli or Candida albicans did not show neo-ethanol formation. Indeed, all samples left at room temperature prior to analysis showed false low detected ethanol amounts. Thus, VITROS alcohol analysis has limitations leading to inaccurate post-mortem specimen analysis. In addition, loss of alcohol from corpses and specimen containers also has an impact on the accuracy of alcohol results in post-mortem cases. © 2014 Australian Academy of Forensic Sciences.
dc.format.mimetypeapplication/pdf
dc.identifier.citationAustralian Journal of Forensic Sciences. Vol 46, No.4 (2014), p.433-441
dc.identifier.doi10.1080/00450618.2014.891653
dc.identifier.issn450618
dc.identifier.other2-s2.0-84907590228
dc.identifier.urihttps://hdl.handle.net/20.500.14740/6403
dc.rights.holderมหาวิทยาลัยศรีนครินทรวิโรฒ
dc.subject.other2 propanol
dc.subject.otherAlcohol
dc.subject.otherButanol
dc.subject.otherGlucose
dc.subject.otherMethanol
dc.subject.otherPropanol
dc.subject.otherAccuracy
dc.subject.otherAlcohol blood level
dc.subject.otherArticle
dc.subject.otherAutopsy
dc.subject.otherCandida albicans
dc.subject.otherContainer
dc.subject.otherEscherichia coli
dc.subject.otherFalse positive result
dc.subject.otherGlucose blood level
dc.subject.otherGlucose urine level
dc.subject.otherHemolysis
dc.subject.otherRoom temperature
dc.subject.otherUrinalysis
dc.titleAccuracy of VITROS alcohol analysis for post-mortem specimens
dc.typeArticle
dspace.entity.typePublication
swu.datasource.scopushttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84907590228&doi=10.1080%2f00450618.2014.891653&partnerID=40&md5=c53269d5a4bbc236d0a7718df68c17cc

Files