Publication:
Fluid temperature at the corneal endothelium during phacoemulsification: comparison of an ophthalmic viscosurgical device and balanced salt solution using the finite element method.

dc.contributor.authorReepolmaha S.
dc.contributor.authorLimtrakarn W.
dc.contributor.authorUthaisang-Tanechpongtamb W.
dc.contributor.authorDechaumphai P.
dc.date.accessioned2021-04-05T03:36:59Z
dc.date.available2021-04-05T03:36:59Z
dc.date.issued2010
dc.date.issuedBE2553
dc.description.abstractPURPOSE: The purpose of this study was to estimate and compare the temperatures of two different anterior chamber solutions at the corneal endothelial level during phacoemulsification. An ophthalmic viscosurgical device (OVD) and balanced salt solution (BSS) were compared using the finite element method (FEM). MATERIALS AND METHODS: The thermal properties of an OVD (IAL-F) and BSS were studied in an experimental setting. A computer-aided design model of ocular anatomy was created in two dimensions. The phaco needle was considered to be the only source of heat generation. Then, the FEM was used to demonstrate the transient temperature distribution in the two ocular models at 10, 20, 30, 40, 50 and 60 s. In these models, the anterior chamber was filled with IAL-F (IAL-F model) or BSS (BSS model). RESULTS: The heat generation rate of the phaco needle was 0.0004 cal/s/mm(2). The maximum corneal endothelial temperatures for the two models at 60 s were 52.67 and 41.57 degrees C, respectively. The experimental IAL-F model showed fewer changes in temperature for any given time and location. At larger distances from the heat source, less temperature variation was detected. CONCLUSION: Phacoemulsification is a potential heat-generating procedure performed between the delicate anterior chamber structures. During this procedure, IAL-F protects the endothelium against heat better than BSS. Copyright 2009 S. Karger AG, Basel.
dc.format.mimetypeapplication/pdf
dc.identifier.citationOphthalmic research. Vol 43, No.4 (2010), p.173-178
dc.identifier.doi10.1159/000272020
dc.identifier.issn14230259
dc.identifier.other2-s2.0-73649122497
dc.identifier.urihttps://hdl.handle.net/20.500.14740/7646
dc.rights.holderScopus
dc.subject.otherAcetic acid derivative
dc.subject.otherBSS solution
dc.subject.otherEye drops
dc.subject.otherMineral
dc.subject.otherSodium chloride
dc.subject.otherViscoelastic substance
dc.subject.otherArticle
dc.subject.otherBody temperature
dc.subject.otherChemistry
dc.subject.otherComparative study
dc.subject.otherComputer simulation
dc.subject.otherCornea endothelium
dc.subject.otherDrug combination
dc.subject.otherFinite element analysis
dc.subject.otherHeat
dc.subject.otherHuman
dc.subject.otherMetabolism
dc.subject.otherPhacoemulsification
dc.subject.otherAcetates
dc.subject.otherBody Temperature
dc.subject.otherComputer Simulation
dc.subject.otherDrug Combinations
dc.subject.otherEndothelium, Corneal
dc.subject.otherFinite Element Analysis
dc.subject.otherHot Temperature
dc.subject.otherHumans
dc.subject.otherMinerals
dc.subject.otherOphthalmic Solutions
dc.subject.otherPhacoemulsification
dc.subject.otherSodium Chloride
dc.subject.otherViscoelastic Substances
dc.titleFluid temperature at the corneal endothelium during phacoemulsification: comparison of an ophthalmic viscosurgical device and balanced salt solution using the finite element method.
dc.typeArticle
dspace.entity.typePublication
swu.datasource.scopushttps://www.scopus.com/inward/record.uri?eid=2-s2.0-73649122497&doi=10.1159%2f000272020&partnerID=40&md5=980280b55570ade8a18b394772be3a0e

Files