Publication:
Principles of the magnetic resonance imaging movie method for articulatory movement

dc.contributor.authorYoshida M.
dc.contributor.authorHonda E.
dc.contributor.authorOzawa E.
dc.contributor.authorInoue-Arai S.M.
dc.contributor.authorOhmori H.
dc.contributor.authorMoriyama K.
dc.contributor.authorOno T.
dc.contributor.authorKurabayashi T.
dc.contributor.authorYoshihara H.
dc.contributor.authorNunthayanon Parakonthun K.
dc.date.accessioned2021-04-05T03:03:15Z
dc.date.available2021-04-05T03:03:15Z
dc.date.issued2019
dc.date.issuedBE2562
dc.description.abstractMagnetic resonance imaging (MRI) has become a critical tool for dental examination. MRI has many advantages over radiographic examination methods, including the lack of a requirement for patient exposure and the ability to capture high-contrast images of various tissue and organ types. However, MRI also has several limitations, including long examination times and the existence of metallic or motion artifacts. A cardiac imaging method using cine sequences was developed in the 1990s. This technique allows for analysis of heart movement and functional blood flow. Moreover, this method has been applied in dentistry. Recent research involving 3 T MRI has led to the achievement of a temporal resolution of < 10 ms, surpassing the frame rate of typical video recording. The current review introduces the history and principles of the cine sequence method and its application to the oral and maxillofacial regions. © 2018, Japanese Society for Oral and Maxillofacial Radiology and Springer Nature Singapore Pte Ltd.
dc.format.mimetypeapplication/pdf
dc.identifier.citationOral Radiology. Vol 35, No.2 (2019), p.91-100
dc.identifier.doi10.1007/s11282-018-0347-7
dc.identifier.issn9116028
dc.identifier.other2-s2.0-85053631518
dc.identifier.urihttps://hdl.handle.net/20.500.14740/5340
dc.rights.holderScopus
dc.subject.otherBlood flow
dc.subject.otherCardiac imaging
dc.subject.otherCine magnetic resonance imaging
dc.subject.otherHeart movement
dc.subject.otherHuman
dc.subject.otherImage artifact
dc.subject.otherImage quality
dc.subject.otherMaxilla
dc.subject.otherMovement (physiology)
dc.subject.otherNuclear magnetic resonance imaging
dc.subject.otherRadiodiagnosis
dc.subject.otherReview
dc.subject.otherSignal noise ratio
dc.subject.otherSound
dc.subject.otherTooth
dc.subject.otherVideorecording
dc.subject.otherArtifact
dc.subject.otherCine magnetic resonance imaging
dc.subject.otherDiagnostic imaging
dc.subject.otherMouth
dc.subject.otherMovement (physiology)
dc.subject.otherMovie
dc.subject.otherNuclear magnetic resonance imaging
dc.subject.otherArtifacts
dc.subject.otherHumans
dc.subject.otherMagnetic Resonance Imaging
dc.subject.otherMagnetic Resonance Imaging, Cine
dc.subject.otherMotion Pictures
dc.subject.otherMouth
dc.subject.otherMovement
dc.titlePrinciples of the magnetic resonance imaging movie method for articulatory movement
dc.typeReview
dspace.entity.typePublication
swu.datasource.scopushttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85053631518&doi=10.1007%2fs11282-018-0347-7&partnerID=40&md5=eddeb8d65b1d45af64f95fb96f60583e

Files