dc.date.issuedBE2559
dc.description.abstractThis paper presented Proportional Resonant (PR) current control of single phase grid connected inverter for PV energy conversion to the utility grid. The synchronization mechanism is Second-Order Generalized Integrator (SOGI) phase locked loop (PLL). The PR current control is regulator in stationary reference frame and an advantage is reduce current distortion. The implemented software using Real Time Workshop and DS1103 Library in Matlab/Simulink environment. The simulation and HIL402 experimental results of single phase inverter has been shown that the current quality is satisfy with IEEE Std. 1547-2003. © 2016 IEEE.
dc.format.mimetypeapplication/pdf
dc.identifier.citation2016 13th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology, ECTI-CON 2016. (2016)
dc.identifier.doi10.1109/ECTICon.2016.7561350
dc.identifier.other2-s2.0-84988855175
dc.identifier.urihttps://hdl.handle.net/20.500.14740/5160
dc.rights.holderScopus
dc.subject.otherElectric current control
dc.subject.otherEnergy conversion
dc.subject.otherMATLAB
dc.subject.otherPhase locked loops
dc.subject.otherGrid connected inverters
dc.subject.otherMATLAB/Simulink environment
dc.subject.otherPhase Locked Loop (PLL)
dc.subject.otherProportional resonant controllers
dc.subject.otherSecondorder generalized integrator (SOGI)
dc.subject.otherSingle phase grid connected inverters
dc.subject.otherStationary reference frames
dc.subject.otherSynchronization mechanisms
dc.subject.otherElectric inverters