Publication:
Loop-Mediated Isothermal Amplification Assay Using Gold Nanoparticles for Detecting Treponema pallidum subspp. pallidum

dc.contributor.authorPhurijaruyangkun S.
dc.contributor.authorTangjitrungrot P.
dc.contributor.authorJaratsing P.
dc.contributor.authorAugkarawaritsawong S.
dc.contributor.authorPongparit S.
dc.contributor.authorVeeramano R.
dc.contributor.authorTanomnuch K.
dc.contributor.authorAreekit S.
dc.contributor.authorChansiri K.
dc.contributor.authorSantiwatanakul S.
dc.contributor.correspondencePhurijaruyangkun S.
dc.contributor.otherSrinakharinwirot University
dc.date.accessioned2025-05-28T07:56:25Z
dc.date.issued2024-10-01
dc.date.issuedBE2567-10-01
dc.description.abstractBackground: Venereal syphilis in humans is caused by Trepenoma pallidum subspp. pallidum. A study has shown that 30,302 individuals in Thailand had syphilis in 2020, with a male-to-female ratio of 1:0.8 and the highest incidence rate at ages between fifteen and twenty-four. Methods: This research aimed to develop a loop-mediated isothermal amplification assay using gold nanoparticles (LAMP-AuNPs). Analytical sensitivity, diagnostic specificity, accuracy, and predictive values for each technique are provided. Results: The diagnosis sensitivities of polymerase chain reaction using agarose gel electrophoresis (PCR-AGE), loop-mediated isothermal amplification assay using agarose gel electrophoresis (LAMP-AGE), and LAMP-AuNPs were 116 ng/µL, 11.6 ng/µL, and 11.6 ng/µL, respectively. We evaluated the analytical specificity using PCR and a LAMP-based assay, and there was no cross-reactivity to Leptospira interrogans, Staphylococcus aureus, Enterococcus faecalis, Escherichia coli, Klebsiella pneumoniae, Acinetobacter baumannii, Pseudomonas aeruginosa, human immunodeficiency virus (HIV), and healthy humans. After analyzing 400 serum samples of patients suspected of syphilis, the LAMP-AGE and LAMP-AuNPs assays displayed 100% diagnostic sensitivity scores, 91% diagnostic specificity scores, 95.5% accuracy rates, 100% positive predictive values (PPVs), and 91% negative predictive values (NPVs), the positive likelihood ratio (LR+) was 11.11, while the negative likelihood ratio (LR−) was 0. Conversely, for PCR assays displayed 100% diagnostic sensitivity scores, 94.5% diagnostic specificity scores, 97.25% accuracy rates, 100% PPVs, and 94.5% NPVs, LR+ was 18.18, and LR− was 0. Conclusions: The LAMP-AuNPs technique demonstrates rapidity, affordability, and convenience, rendering it well-suited for point-of-care applications in the diagnosis, prevention, and management of pathogenic infections.
dc.identifier.citationDiagnostics Vol.14 No.20 (2024)
dc.identifier.doi10.3390/diagnostics14202323
dc.identifier.eissn20754418
dc.identifier.scopus2-s2.0-85207528908
dc.identifier.urihttps://hdl.handle.net/20.500.14740/20782
dc.rights.holderSCOPUS
dc.subjectBiochemistry, Genetics and Molecular Biology
dc.titleLoop-Mediated Isothermal Amplification Assay Using Gold Nanoparticles for Detecting Treponema pallidum subspp. pallidum
dc.typeArticle
dspace.entity.typePublication
oaire.citation.issue20
oaire.citation.titleDiagnostics
oaire.citation.volume14
oairecerif.author.affiliationRangsit University
oairecerif.author.affiliationFaculty of Medicine, Srinakharinwirot University
oairecerif.author.affiliationSrinakharinwirot University
swu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85207528908&origin=inward

Files