Publication:
Graphene/polyvinylpyrrolidone/polyaniline nanocomposite-modified electrode for simultaneous determination of parabens by high performance liquid chromatography

dc.contributor.authorKajornkavinkul S.
dc.contributor.authorPunrat E.
dc.contributor.authorSiangproh W.
dc.contributor.authorRodthongkum N.
dc.contributor.authorPraphairaksit N.
dc.contributor.authorChailapakul O.
dc.date.accessioned2021-04-05T03:24:17Z
dc.date.available2021-04-05T03:24:17Z
dc.date.issued2016
dc.date.issuedBE2559
dc.description.abstractA nanocomposite of graphene (G), polyvinylpyrrolidone (PVP) and polyaniline (PANI) modified onto screen-printed carbon electrode (SPCE) using an electrospraying technique was developed for simultaneous determination of five parabens in beverages and cosmetic products by high performance liquid chromatography. PVP and PANI were used as the dispersing agents of graphene, and also for the enhancement of electrochemical conductivity of the electrode. The electrochemical behavior of each paraben was investigated using the G/PVP/PANI nanocomposite-modified SPCE, compared to the unmodified SPCE. Using HPLC along with amperometric detection at a controlled potential of +1.2 V vs Ag/AgCl, the chromatogram of five parabens obtained from the modified SPCE exhibits well defined peaks and higher current response than those of its unmodified counterpart. Under the optimal conditions, the calibration curves of five parabens similarly provide a linear range between 0.1 and 30 μg mL-1 with the detection limits of 0.01 μg mL-1for methyl paraben (MP), ethyl paraben (EP) and propyl paraben (PP), 0.02 and 0.03 μg mL-1 for isobutyl paraben (IBP) and butyl paraben (BP), respectively. Furthermore, this proposed method was applied for the simultaneous determination of five parabens in real samples including a soft drink and a cosmetic product with satisfactory results, yielding the recovery in the range of 90.4-105.0%. © 2015 Elsevier B.V.
dc.format.mimetypeapplication/pdf
dc.identifier.citationTalanta. Vol 148, (2016), p.655-660
dc.identifier.doi10.1016/j.talanta.2015.05.044
dc.identifier.issn399140
dc.identifier.other2-s2.0-84949097632
dc.identifier.urihttps://hdl.handle.net/20.500.14740/5721
dc.rights.holderScopus
dc.subject.otherBeverages
dc.subject.otherChromatographic analysis
dc.subject.otherCosmetics
dc.subject.otherElectrochemical electrodes
dc.subject.otherGraphene
dc.subject.otherHigh performance liquid chromatography
dc.subject.otherLiquids
dc.subject.otherNanocomposites
dc.subject.otherPolyaniline
dc.subject.otherPropylparaben
dc.subject.otherAmperometric detection
dc.subject.otherElectrochemical behaviors
dc.subject.otherElectrospraying
dc.subject.otherModified electrodes
dc.subject.otherPolyanilines (PAni)
dc.subject.otherPolyvinyl pyrrolidone
dc.subject.otherScreen-printed carbon electrodes
dc.subject.otherSimultaneous determinations
dc.subject.otherParabens
dc.subject.other4 hydroxybenzoic acid ester
dc.subject.otherAniline derivative
dc.subject.otherGraphite
dc.subject.otherNanocomposite
dc.subject.otherPolyaniline
dc.subject.otherPovidone
dc.subject.otherChemistry
dc.subject.otherDevices
dc.subject.otherElectrospray mass spectrometry
dc.subject.otherHigh performance liquid chromatography
dc.subject.otherIon selective electrode
dc.subject.otherProcedures
dc.subject.otherAniline Compounds
dc.subject.otherChromatography, High Pressure Liquid
dc.subject.otherGraphite
dc.subject.otherIon-Selective Electrodes
dc.subject.otherNanocomposites
dc.subject.otherParabens
dc.subject.otherPovidone
dc.subject.otherSpectrometry, Mass, Electrospray Ionization
dc.titleGraphene/polyvinylpyrrolidone/polyaniline nanocomposite-modified electrode for simultaneous determination of parabens by high performance liquid chromatography
dc.typeArticle
dspace.entity.typePublication
swu.datasource.scopushttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84949097632&doi=10.1016%2fj.talanta.2015.05.044&partnerID=40&md5=7e13d3160ea4a8f0519d41f19e5075fe

Files