Publication:
Simple flow system with in-line gas-diffusion unit for determination of ethanol employing hypsochromic shift of visible absorbance band of methyl orange

dc.contributor.authorRatanawimarnwong N.
dc.contributor.authorSinpun M.
dc.contributor.authorChankaw P.
dc.contributor.authorChoengchan N.
dc.contributor.authorNacapricha D.
dc.date.accessioned2021-04-05T03:01:58Z
dc.date.available2021-04-05T03:01:58Z
dc.date.issued2020
dc.date.issuedBE2563
dc.description.abstractThe effect of solvent composition on the uv–visible spectrum of methyl orange was investigated for application to the quantitative determination of ethanol. At fixed pH, there was a hypsochromic shift of the absorbance band of methyl orange with increasing ethanol concentration. Using acetate buffer at pH 3.40 the change of absorbance at 530 nm of a solution of methyl orange containing known concentrations of standard ethanol was measured to provide a calibration curve. In order to apply this method to the analysis of alcoholic samples, such as distilled spirits, blended spirits and liquid herbal medicines, a simple gas-diffusion unit coupled with flow system was employed to separate the ethanol from sample matrices. Using the gas diffusion-flow system and employing an evaporation time of 2 min, a linear calibration range of 5–45% (v/v) ethanol was achieved ((ΔA = (0.0078 ± 0.0002)x(ethanol, %(v/v)) + (0.040 ± 0.005)), r2 = 0.998). The limit of detection (3σ blank/slope) was 2.23% (v/v). The developed gas diffusion-flow system was applied to the analysis of colorless distilled spirits, yellow blended spirits and dark brown herbal medicines that are available in the local markets of Bangkok, Thailand. Validation of the method was carried out by comparing the results with analysis using gas chromatography. There was no statistically significant difference at the 95% confidence level for all alcoholic samples analyzed. © 2019 Elsevier B.V.
dc.format.mimetypeapplication/pdf
dc.identifier.citationTalanta. Vol 206, (2020)
dc.identifier.doi10.1016/j.talanta.2019.120234
dc.identifier.issn399140
dc.identifier.other2-s2.0-85070545728
dc.identifier.urihttps://hdl.handle.net/20.500.14740/4856
dc.rights.holderScopus
dc.subject.otherAzo dyes
dc.subject.otherCalibration
dc.subject.otherCitrus fruits
dc.subject.otherDiffusion in gases
dc.subject.otherEthanol
dc.subject.otherGas chromatography
dc.subject.otherGases
dc.subject.otherMedicine
dc.subject.otherPlant extracts
dc.subject.otherCalibration curves
dc.subject.otherEffect of solvents
dc.subject.otherEthanol concentrations
dc.subject.otherGas diffusion
dc.subject.otherHypsochromic shifts
dc.subject.otherMethyl Orange
dc.subject.otherQuantitative determinations
dc.subject.otherStatistically significant difference
dc.subject.otherOrganic solvents
dc.titleSimple flow system with in-line gas-diffusion unit for determination of ethanol employing hypsochromic shift of visible absorbance band of methyl orange
dc.typeArticle
dspace.entity.typePublication
swu.datasource.scopushttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85070545728&doi=10.1016%2fj.talanta.2019.120234&partnerID=40&md5=d71d731d4201117f413038135d1db1cf

Files