Publication: Influence of abutment connections on strain distribution for implant-supported 4-units bridge
| dc.contributor.advisor | Napapa Aimjirakul | en |
| dc.contributor.author | Jekita Siripru | en |
| dc.contributor.orgunit | Srinakharinwirot University | |
| dc.date.accessioned | 2024-01-15T01:31:44Z | |
| dc.date.available | 2024-01-15T01:31:44Z | |
| dc.date.created | 2023 | |
| dc.date.createdBE | 2566 | |
| dc.date.issued | 2023-12-15 | |
| dc.date.issuedBE | 2566-12-15 | |
| dc.description.abstract | The purpose of this study is to evaluate the microstrain around two non-parallel implant-supported bridges with different types of abutment connections (engaging, non-engaging and scrp) and the different positions of abutments. The four models simulating the mandibular unilateral free end were fabricated. There were eight implants (4.0 x 10 mm and 5.0 x 10 mm) were inserted in four models in the position of the second premolar (45) that paralleled the long axis and the second molar (47) that tilted 15° from the long axis to support a 4-unit zirconia bridge, according to different abutment combinations: engaging and engaging abutments (angled abutment), both non-engaging abutments, both SCRP abutments, and engaging and non-engaging abutments. Four strain gauges were mounted buccally, lingually, mesially, and distally adjacent to each implant. Applied vertical static load: 300 N. Microstrains were recorded and analyzed statistically by three-way repeated ANOVA and pairwise comparisons (α=.5). The result showed group two (non-engaging, non-engaging) showed the highest compressive microstrains (-52.975), followed by control group one (engaging, angled abutment) (-25.239), and group three (SCRP-SCRP) had the lowest compressive microstrains (-14.505), while only group four (engaging, angled abutment) had tensile microstrains (0.418). The microstrains in groups three and four were significantly lower than those in the control group (α=.5) Area 45 showed compressive microstrains (-47.06), while area 47 had tensile microstrains (+0.91), with microstrains in area 45 being significantly higher than in area 47 (α=.5) In conclusion, the type and position of the abutment connection have significantly affected microstrain at the implant-bone interface of two non-parallel implant-supported bridges. Both SCRP abutments for two non-parallel implant-supported bridges provided optimal microstrain distribution on bone. | en |
| dc.format.mimetype | application/pdf | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14740/52433 | |
| dc.language.iso | eng | |
| dc.publisher | Srinakharinwirot University | |
| dc.rights | ผลงานนี้เผยแพร่ภายใต้ สัญญาอนุญาตครีเอทีฟคอมมอนส์แบบ แสดงที่มา-ไม่ใช้เพื่อการค้า-ไม่ดัดแปลง 4.0 (CC BY-NC-ND 4.0) | |
| dc.rights.holder | Srinakharinwirot University | |
| dc.source.uri | https://ir-ithesis.swu.ac.th/handle/123456789/2667 | |
| dc.subject | Microstrain | en |
| dc.subject | Implant-supported bridges | en |
| dc.subject | Abutment connection | en |
| dc.subject | Strain gauge | en |
| dc.subject.classification | Dentistry | en |
| dc.subject.classification | Professional, scientific and technical activities | en |
| dc.subject.classification | Dental studies | en |
| dc.title | Influence of abutment connections on strain distribution for implant-supported 4-units bridge | |
| dc.title.alternative | อิทธิพลของบริเวณเชื่อมต่อของรากเทียมและหลักยึดต่อการกระจายความเครียดสำหรับรากเทียมรองรับสะพานฟัน 4 ซี่ | |
| dc.type | Thesis | en |
| dcterms.accessRights | Open Access | |
| dspace.entity.type | Publication | |
| thesis.degree.discipline | Clinical Dentistry | en |
| thesis.degree.grantor | Srinakharinwirot University | |
| thesis.degree.level | Masters | en |
| thesis.degree.name | MASTER OF SCIENCE | en |
Files