Please use this identifier to cite or link to this item: https://ir.swu.ac.th/jspui/handle/123456789/13360
Full metadata record
DC FieldValueLanguage
dc.contributor.authorChinsongkram B.
dc.contributor.authorChaikeeree N.
dc.contributor.authorSaengsirisuwan V.
dc.contributor.authorHorak F.B.
dc.contributor.authorBoonsinsukh R.
dc.date.accessioned2021-04-05T03:23:30Z-
dc.date.available2021-04-05T03:23:30Z-
dc.date.issued2016
dc.identifier.issn319023
dc.identifier.other2-s2.0-84989933423
dc.identifier.urihttps://ir.swu.ac.th/jspui/handle/123456789/13360-
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84989933423&doi=10.2522%2fptj.20150621&partnerID=40&md5=5facf305bd62ad60931974e500875825
dc.description.abstractBackground. The reliability and convergent validity of the Balance Evaluation Systems Test (BESTest) in people with subacute stroke have been established, but its responsiveness to rehabilitation has not been examined. Objective. The study objective was to compare the responsiveness of the BESTest with those of other clinical balance tools in people with subacute stroke. Design. This was a prospective cohort study. Methods. Forty-nine people with subacute stroke (mean age=57.8 years, SD=11.8) participated in this study. Five balance measures—the BESTest, the Mini-BESTest, the Berg Balance Scale, the Postural Assessment Scale for Stroke Patients, and the Community Balance and Mobility Scale (CB&M)—were used to measure balance performance before and after rehabilitation or before discharge from the hospital, whichever came first. The internal responsiveness of each balance measure was classified with the standardized response mean (SRM); changes in Berg Balance Scale scores of greater than 7 were used as the external standard for determining the external responsiveness. Analysis of the receiver operating characteristic curve was used to determine the accuracy and cutoff scores for identifying participants with balance improvement. Results. Participants received 13.7 days (SD=9.3, range=5–44) of physical therapy rehabilitation. The internal responsiveness of all balance measures, except for the CB&M, was high (SRM=0.9–1.2). The BESTest had a higher SRM than the Mini-BESTest and the CB&M, indicating that the BESTest was more sensitive for detecting balance changes than the Mini-BESTest and the CB&M. In addition, compared with other balance measures, the BESTest had no floor, ceiling, or responsive ceiling effects. The results also indicated that the percentage of participants with no change in scores after rehabilitation was smaller with the BESTest than with the Mini-BESTest and the CB&M. With regard to the external responsiveness, the BESTest had higher accuracy, sensitivity, specificity, and posttest accuracy than the Postural Assessment Scale for Stroke Patients and the CB&M for identifying participants with balance improvement. Changes in BESTest scores of 10% or more indicated changes in balance performance. Limitations. A limitation of this study was the difference in the time periods between the first and the second assessments across participants. Conclusions. The BESTest was the most sensitive scale for assessing balance recovery in participants with subacute stroke because of its high internal and external responsiveness and lack of floor and ceiling effects. © 2016 American Physical Therapy Association.
dc.subjectadult
dc.subjectBerg Balance Scale
dc.subjectclinical study
dc.subjectcohort analysis
dc.subjectdiagnostic test accuracy study
dc.subjecthospital
dc.subjecthuman
dc.subjectmiddle aged
dc.subjectphysiotherapy
dc.subjectreceiver operating characteristic
dc.subjectrehabilitation
dc.subjectremission
dc.subjectstroke patient
dc.subjectbody equilibrium
dc.subjectcerebrovascular accident
dc.subjectdisability
dc.subjectfemale
dc.subjectmale
dc.subjectpathophysiology
dc.subjectphysiology
dc.subjectprospective study
dc.subjectreproducibility
dc.subjectstroke rehabilitation
dc.subjectDisability Evaluation
dc.subjectFemale
dc.subjectHumans
dc.subjectMale
dc.subjectMiddle Aged
dc.subjectPostural Balance
dc.subjectProspective Studies
dc.subjectReproducibility of Results
dc.subjectStroke
dc.subjectStroke Rehabilitation
dc.titleResponsiveness of the balance evaluation systems test (BESTest) in people with subacute stroke
dc.typeArticle
dc.rights.holderScopus
dc.identifier.bibliograpycitationPhysical Therapy. Vol 96, No.10 (2016), p.1638-1647
dc.identifier.doi10.2522/ptj.20150621
Appears in Collections:Scopus 1983-2021

Files in This Item:
There are no files associated with this item.


Items in SWU repository are protected by copyright, with all rights reserved, unless otherwise indicated.