Please use this identifier to cite or link to this item:
https://ir.swu.ac.th/jspui/handle/123456789/29514
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Siricharoenpanitch A. | |
dc.contributor.author | Wiriyasart S. | |
dc.contributor.author | Vengsungnle P. | |
dc.contributor.author | Naphon N. | |
dc.contributor.author | Naphon P. | |
dc.contributor.other | Srinakharinwirot University | |
dc.date.accessioned | 2023-11-15T02:08:49Z | - |
dc.date.available | 2023-11-15T02:08:49Z | - |
dc.date.issued | 2023 | |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85132667327&doi=10.1080%2f01457632.2022.2068219&partnerID=40&md5=462e1b8f5fe38017ee19a13c7f377111 | |
dc.identifier.uri | https://ir.swu.ac.th/jspui/handle/123456789/29514 | - |
dc.description.abstract | The present study considers the effects of the electromagnetic field and pulsating flow on nanofluids heat transfer and flow characteristics in the three-start helically fluted tube. The experiments are performed using anofluids with the Reynolds number varying from 8000 to 13000, and with an Fe3O4/water nanofluids (Ferrofluid) concentration of 0.005% by volume with and without an electromagnetic field effect. The measured results are verified with the predicted results from the proposed correlations and the published experimental results. As a result of the disturbed flow boundary layer, higher swirling Brownian motion, higher local thermal conductivity, and the mixing of turbulent intensity, the heat transfer performance also increases. For a given pulsating flow of 30 Hz, the Nusselt number enhancement increases significantly to 137.7% and 156.7% for the helical depth ratios of 0.028 and 0.093, respectively. The helically fluted tube with a helical depth ratio of 0.093 and a helical pitch ratio of 0.93 yields the highest Nusselt number improvement. The Nusselt number under the electromagnetic field effect increases by 19.0% and 14.4% for the pulsating flow of 30 Hz and 20 Hz, respectively. Finally, a comprehensive evaluation index is applied to estimate thermo-hydraulic performance. It is found that the comprehensive evaluation index increases with the increasing Reynolds number at first and then decreases as the Reynolds number increases further. © 2022 Taylor & Francis Group, LLC. | |
dc.publisher | Taylor and Francis Ltd. | |
dc.title | Heat Transfer of Ferrofluid in Fluted Tubes with an Electromagnetic Field | |
dc.type | Article | |
dc.rights.holder | Scopus | |
dc.identifier.bibliograpycitation | Heat Transfer Engineering. Vol 44, No.5 (2023), p.426-441 | |
dc.identifier.doi | 10.1080/01457632.2022.2068219 | |
Appears in Collections: | Scopus 2023 |
Files in This Item:
There are no files associated with this item.
Items in SWU repository are protected by copyright, with all rights reserved, unless otherwise indicated.