DSpace Repository

A Development of electrode probes for imaging precancerous lesions with electrical impedance tomography technique: A phantom study

Show simple item record

dc.contributor.author Ngamdi N.
dc.contributor.author Sriwilai J.
dc.contributor.author Trongwongsa T.
dc.contributor.author Ouypornkochagorn T.
dc.contributor.other Srinakharinwirot University
dc.date.accessioned 2023-11-15T02:09:10Z
dc.date.available 2023-11-15T02:09:10Z
dc.date.issued 2024
dc.identifier.uri https://www.scopus.com/inward/record.uri?eid=2-s2.0-85165431412&doi=10.6180%2fjase.202401_27%281%29.0006&partnerID=40&md5=c822a6a0fe8fde06ef078eb467ec6c68
dc.identifier.uri https://ir.swu.ac.th/jspui/handle/123456789/29575
dc.description.abstract Cervical abnormality screening can reduce the risk of getting cancer. Screening methods mostly depend on laboratory investigation which requires equipment, time, and pathologist experience. Electrical bioimpedance has been reported that can be used to identify the presence of cervical intraepithelial neoplasia (CIN) since the conductivity of CIN could be 4-5 times higher than that of normal tissue. In this study, an electrode probe having 8 round electrodes is developed with 1.5 mm-electrode distance. Tissue conductivity can be directly estimated with the probe based on the four-point measurement method, and the image of conductivity distribution can be reconstructed at the same time. The simulation result showed that when tissue thickness was thicker than 4 mm, the commonly-used formula for estimating conductivity is applicable regardless of the electrode shape, but a correction factor was needed with a value up to 1.2 when the thickness was down to 1 mm. The localization performance of the reconstruction images was investigated in a phantom experiment-on a piece of sausage with a burning spot on the surface. Five current excitations were performed from 2 kHz to 125 kHz. The burning surface could be located with a localization error of 0.23 mm with a frequency higher than 2 kHz. However, artifacts were still observable in the images at the boundary region of the electrode array. Thus, increasing the number of electrodes and increasing the probe tip area or decreasing the electrode diameter are still recommended. © Journal of Applied Science and Engineering (Taiwan). All rights reserved.
dc.publisher Tamkang University
dc.subject Cervical precancerous tissues
dc.subject Electrode probe
dc.subject Reconstruction
dc.subject Tissue conductivity
dc.title A Development of electrode probes for imaging precancerous lesions with electrical impedance tomography technique: A phantom study
dc.type Article
dc.rights.holder Scopus
dc.identifier.bibliograpycitation Journal of Applied Science and Engineering (Taiwan). Vol 27, No.1 (2024), p.1901-1910
dc.identifier.doi 10.6180/jase.202401_27(1).0006