dc.contributor.author |
Zein M. |
|
dc.contributor.author |
Wylegala A. |
|
dc.contributor.author |
Sripawadkul W. |
|
dc.contributor.author |
Al Bayyat G. |
|
dc.contributor.author |
Alvarez O.P. |
|
dc.contributor.author |
Gutierrez A.J. |
|
dc.contributor.author |
Guerrero M.A. |
|
dc.contributor.author |
Galor A. |
|
dc.contributor.author |
Karp C.L. |
|
dc.contributor.other |
Srinakharinwirot University |
|
dc.date.accessioned |
2023-11-15T02:08:14Z |
|
dc.date.available |
2023-11-15T02:08:14Z |
|
dc.date.issued |
2023 |
|
dc.identifier.uri |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85149999473&doi=10.1097%2fj.jcrs.0000000000001090&partnerID=40&md5=713a8fb7190c810cc4c9042287200fcd |
|
dc.identifier.uri |
https://ir.swu.ac.th/jspui/handle/123456789/29281 |
|
dc.description.abstract |
To assess the effect of mask wear on corneal topography and tomography readings.Setting:Tertiary ophthalmic center.Design:Prospective, observational, comparative study.Methods:Subjects underwent imaging with the Tomey TMS-4a topographer and the Oculus Pentacam HR tomographer. Imaging was performed without a mask, and then testing was repeated while wearing 3 different masks: Halyard Level 2, Halyard Level 3, and KN95. Measurements during mask wear were compared with measurements without a mask. The Kruskal-Wallis analysis of variance grouped test was used to compare mean differences without vs with mask wear on measurements. The Chi-square test was used to compare frequency of differences between different masks and against-the-rule vs with-the-rule astigmatism. The frequencies of clinically significant changes in axis of astigmatism, magnitude of astigmatism, and mean keratometry (K) values were calculated.Results:52 eyes were included in the study with a mean age of 34.71. Mask wear did not show statistically significant differences in mean topography and tomography measurements compared with without mask wear for all parameters. However, the majority, 53% (83/156) had a >10 degrees and 41% (64/156) had >15 degrees change in axis of astigmatism on topography when wearing a mask compared with no mask wear.Conclusions:Mask wear did not result in statistically significant mean changes in K readings on topography and tomography. However, the axis of astigmatism varied >10 degrees in most of the patients. Axis determination should be interpreted with caution regarding refractive surgery and/or toric intraocular lens planning in individuals whose measurements were obtained while wearing a mask. © 2023 Elsevier Inc.. All rights reserved. |
|
dc.publisher |
Lippincott Williams and Wilkins |
|
dc.title |
Corneal topography and tomography readings with mask wear during the COVID-19 pandemic |
|
dc.type |
Article |
|
dc.rights.holder |
Scopus |
|
dc.identifier.bibliograpycitation |
Journal of Cataract and Refractive Surgery. Vol 49, No.3 (2023), p.285-291 |
|
dc.identifier.doi |
10.1097/j.jcrs.0000000000001090 |
|