DSpace Repository

A Comparison of Shear Wave Elastography between Normal Myometrium, Uterine Fibroids, and Adenomyosis: A Cross-Sectional Study

Show simple item record

dc.contributor.author Pongpunprut S.
dc.contributor.author Panburana P.
dc.contributor.author Wibulpolprasert P.
dc.contributor.author Waiyaput W.
dc.contributor.author Sroyraya M.
dc.contributor.author Chansoon T.
dc.contributor.author Sophonsritsuk A.
dc.date.accessioned 2022-12-14T03:17:24Z
dc.date.available 2022-12-14T03:17:24Z
dc.date.issued 2022
dc.identifier.issn 2008076X
dc.identifier.uri https://www.scopus.com/inward/record.uri?eid=2-s2.0-85124380366&doi=10.22074%2fIJFS.2021.523075.1074&partnerID=40&md5=6d0e73f28d2be3a30220366f0e3493de
dc.identifier.uri https://ir.swu.ac.th/jspui/handle/123456789/27460
dc.description.abstract Background: The differential diagnosis between uterine fibroid and adenomyosis is sometimes difficult; a precise diagnosis is required in women with infertility because of the different choice of treatments. Ultrasound elastography (UE) is a novel technique to evaluate the elasticity or the stiffness of the tissue of interest. The present study aims to compare UE shear wave velocity (SWV) among normal uterine myometrium, uterine fibroid, and adenomyosis, and assess the accuracy of shear wave elastography in the diagnosis of adenomyosis. Materials and Methods: This cross-sectional study recruited 25 subjects for each group (control, adenomyosis, and fibroid) from April 2019 to April 2020. Transvaginal UE using an Aplio 500 (Toshiba Medical Systems, Japan) with ultrasound mapping for point of tissue biopsy was performed for all subjects. The diagnosis was confirmed by histol-ogy. Masson’s trichrome staining for collagen was performed and quantified. Results: The mean ± standard deviation (SD) for SWV was 3.44 ± 0.95 m/seconds (control group), 4.63 ± 1.45 m/ seconds (adenomyosis group), and 4.53 ± 1.07 m/seconds (fibroid group). The mean SWV differed when comparing normal myometrium and adenomyosis after adjustments for age and endometrial pathology (P=0.019). The cut-off point of SWV at 3.465 m/seconds could differentiate adenomyosis from the normal uterus with an 80% sensitivity, 80% specificity, and an area under the curve (AUC) of 0.80 (95% confidence interval [CI]: 0.68-0.93) (P<0.001). No significant difference in SWV between the adenomyosis and fibroid groups was detected. Conclusion: Shear wave elastography could be an alternative tool to distinguish between normal myometrium and adeno-myosis; however, it could not differentiate adenomyosis from uterine fibroid or uterine fibroid from normal myometrium. © 2022, Royan Institute (ACECR). All rights reserved.
dc.language en
dc.subject collagen
dc.subject adenomyosis
dc.subject adult
dc.subject aged
dc.subject area under the curve
dc.subject Article
dc.subject biopsy
dc.subject clinical trial
dc.subject controlled clinical trial
dc.subject controlled study
dc.subject cross-sectional study
dc.title A Comparison of Shear Wave Elastography between Normal Myometrium, Uterine Fibroids, and Adenomyosis: A Cross-Sectional Study
dc.type Article
dc.rights.holder Scopus
dc.identifier.bibliograpycitation International Journal of Fertility and Sterility. Vol 16, No.1 (2022), p.49-54
dc.identifier.doi 10.22074/IJFS.2021.523075.1074


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account

Statistics