DSpace Repository

Enzyme-free impedimetric biosensor-based molecularly imprinted polymer for selective determination of L-hydroxyproline

Show simple item record

dc.contributor.author Jesadabundit W.
dc.contributor.author Jampasa S.
dc.contributor.author Patarakul K.
dc.contributor.author Siangproh W.
dc.contributor.author Chailapakul O.
dc.date.accessioned 2022-03-10T13:17:32Z
dc.date.available 2022-03-10T13:17:32Z
dc.date.issued 2021
dc.identifier.issn 9565663
dc.identifier.other 2-s2.0-85107970643
dc.identifier.uri https://ir.swu.ac.th/jspui/handle/123456789/17560
dc.identifier.uri https://www.scopus.com/inward/record.uri?eid=2-s2.0-85107970643&doi=10.1016%2fj.bios.2021.113387&partnerID=40&md5=2e50a5cf733990c006251387cb5555e6
dc.description.abstract This study first reported enzyme-free impedimetric biosensor-based molecularly imprinted polymers for selective and sensitive determination of L-hydroxyproline (L-hyp), a biomarker for the early diagnosis of bone diseases. In recent study, utilizing a single 3-aminophenylboronic acid (3-APBA) to create imprinted surfaces could result in a strong interaction and difficulty in removal of a template molecule. Hence, a mixture of monomer solution containing 3-APBA and o-phenylenediamine (OPD) in the presence of the L-hyp molecule was co-electropolymerized onto the screen-printed electrode using cyclic voltammetry (CV) to eradicate this mentioned limitation. The detection principle of this sensor is relied on alteration of mediator's charge transfer resistance (Rct) that could be obstructed by L-hyp occupied in imprinted surface. The successfully fabricated biosensor was explored by scanning electron microscopy (SEM), Fourier-transform infrared spectroscopy (FTIR), and confocal scanning microscopy. Furthermore, the effect of polymer composition on the Rct response was systematically investigated. The result exhibited that the mixture of monomers could provide the highest change of Rct due to high selectivity from esterification of 3-APBA and from hydrogen bond of OPD surrounding the template. The sensor showed a significant increase in Rct in the presence of L-hyp, whereas no observable resistance change was detected in the absence thereof. The calibration curve was obtained in the range from 0.4 to 25 μg mL−1 with limits of detection (3SDblank/Slope) and quantification (10SDblank/Slope) of 0.13 and 0.42 μg mL−1, respectively. This biosensor exhibited high selectivity and sensitivity and was successfully applied to determine L-hyp in human serum samples with satisfactory results. © 2021 Elsevier B.V.
dc.language en
dc.subject Biosensors
dc.subject Bone
dc.subject Charge transfer
dc.subject Cyclic voltammetry
dc.subject Diagnosis
dc.subject Enzymes
dc.subject Fourier transform infrared spectroscopy
dc.subject Hydrogen bonds
dc.subject Mixtures
dc.subject Molecules
dc.subject Monomers
dc.subject Scanning electron microscopy
dc.subject 3-Aminophenylboronic acid
dc.subject Bone disease
dc.subject Electrochemical-impedance spectroscopies
dc.subject High selectivity
dc.subject Impedimetric biosensors
dc.subject L hydroxyprolines
dc.subject Molecularly Imprinted Polymer
dc.subject Nonenzymatic sensor
dc.subject O-Phenylenediamine
dc.subject Selective determination
dc.subject Electrochemical impedance spectroscopy
dc.subject 1,2 phenylenediamine
dc.subject hydroxyproline
dc.subject polymer
dc.subject hydroxyproline
dc.subject molecularly imprinted polymer
dc.subject Article
dc.subject bone disease
dc.subject calibration
dc.subject confocal laser scanning microscopy
dc.subject cyclic voltammetry
dc.subject esterification
dc.subject Fourier transform infrared spectroscopy
dc.subject human
dc.subject hydrogen bond
dc.subject impedance spectroscopy
dc.subject limit of detection
dc.subject molecular imprinting
dc.subject normal human
dc.subject scanning electron microscopy
dc.subject electrochemical analysis
dc.subject electrode
dc.subject genetic procedures
dc.subject Biosensing Techniques
dc.subject Electrochemical Techniques
dc.subject Electrodes
dc.subject Humans
dc.subject Hydroxyproline
dc.subject Limit of Detection
dc.subject Molecular Imprinting
dc.subject Molecularly Imprinted Polymers
dc.title Enzyme-free impedimetric biosensor-based molecularly imprinted polymer for selective determination of L-hydroxyproline
dc.type Article
dc.rights.holder Scopus
dc.identifier.bibliograpycitation Biosensors and Bioelectronics. Vol 191, No. (2021)
dc.identifier.doi 10.1016/j.bios.2021.113387


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account

Statistics