DSpace Repository

Effect of heat source area on the thermal resistance of the wick columns vapor chambers

Show simple item record

dc.contributor.author Wiriyasart S.
dc.contributor.author Naphon P.
dc.date.accessioned 2021-04-05T03:24:14Z
dc.date.available 2021-04-05T03:24:14Z
dc.date.issued 2016
dc.identifier.issn 1738494X
dc.identifier.other 2-s2.0-84957938383
dc.identifier.uri https://ir.swu.ac.th/jspui/handle/123456789/13484
dc.identifier.uri https://www.scopus.com/inward/record.uri?eid=2-s2.0-84957938383&doi=10.1007%2fs12206-016-0147-0&partnerID=40&md5=40e1c30bf86f8b1923d9a982f8237cd4
dc.description.abstract The results of the spreading thermal resistance, heat transfer and flow characteristics of the vapor chamber embedded with plate fin are investigated. The experiments are performed with the vapor chambers with wick plate and wick columns embedded plate fin. Parametric studies including different heat fluxes, heated surface areas, flow rate of coolants on the cooling performance in terms of the spreading thermal resistance and heat transfer characteristics are considered. A three-dimensional heat and mass transfer model for the vapor chamber with wick plate and wick columns are developed. The velocity and pressure distributions of liquid phase and vapor phase inside the vapor chamber obtained from the simulation are shown. By comparing the experimental results with numerical results, reasonable agreement is obtained. It can be found that the heat input and heat source area have significant effect on the decreasing of the boiling and condensation thermal resistances while they are slightly effect on the decreasing of the convective thermal resistance. Due to the wick plate and wick columns, the capillary force has significant effect on the working fluid circulation, evaporation rate and flow directions of the liquid and vapor phases inside the vapor chamber. The results of this study are of technological importance for the efficient design of cooling system of the personal computer or electronic devices to enhance cooling performance of the vapor chamber. © 2016, The Korean Society of Mechanical Engineers and Springer-Verlag Berlin Heidelberg.
dc.subject Cooling
dc.subject Electronic cooling
dc.subject Fins (heat exchange)
dc.subject Heat transfer
dc.subject Mass transfer
dc.subject Personal computers
dc.subject Thermoelectric equipment
dc.subject Boiling and condensations
dc.subject Cooling performance
dc.subject Heat and mass transfer models
dc.subject Heat sources
dc.subject Heat transfer and flows
dc.subject Heat transfer characteristics
dc.subject Plate fins
dc.subject Spreading thermal resistance
dc.subject Heat resistance
dc.title Effect of heat source area on the thermal resistance of the wick columns vapor chambers
dc.type Article
dc.rights.holder Scopus
dc.identifier.bibliograpycitation Journal of Mechanical Science and Technology. Vol 30, No.2 (2016), p.933-942
dc.identifier.doi 10.1007/s12206-016-0147-0