Please use this identifier to cite or link to this item:
https://ir.swu.ac.th/jspui/handle/123456789/27161
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Samper I.C. | |
dc.contributor.author | McMahon C.J. | |
dc.contributor.author | Schenkel M.S. | |
dc.contributor.author | Clark K.M. | |
dc.contributor.author | Khamcharoen W. | |
dc.contributor.author | Anderson L.B.R. | |
dc.contributor.author | Terry J.S. | |
dc.contributor.author | Gallichotte E.N. | |
dc.contributor.author | Ebel G.D. | |
dc.contributor.author | Geiss B.J. | |
dc.contributor.author | Dandy D.S. | |
dc.contributor.author | Henry C.S. | |
dc.date.accessioned | 2022-12-14T03:16:56Z | - |
dc.date.available | 2022-12-14T03:16:56Z | - |
dc.date.issued | 2022 | |
dc.identifier.issn | 32700 | |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85126587155&doi=10.1021%2facs.analchem.1c04966&partnerID=40&md5=5b0c73b87fca472b383d55995cb7ac20 | |
dc.identifier.uri | https://ir.swu.ac.th/jspui/handle/123456789/27161 | - |
dc.description.abstract | Point-of-care (POC) methods currently available for detecting SARS-CoV-2 infections still lack accuracy. Here, we report the development of a highly sensitive electrochemical immunoassay capable of quantitatively detecting the presence of the SARS-CoV-2 virus in patient nasopharyngeal samples using stencil-printed carbon electrodes (SPCEs) functionalized with capture antibodies targeting the SARS-CoV-2 nucleocapsid protein (N protein). Samples are added to the electrode surface, followed by horseradish peroxidase (HRP)-conjugated detection antibodies also targeting the SARS-CoV-2 N protein. The concentration of the virus in samples is quantified using chronoamperometry in the presence of 3,3′5,5′-tetramethylbenzidine. Limits of detection equivalent to less than 50 plaque forming units/mL (PFU/mL) were determined with virus sample volumes of 20 μL. No cross-reactivity was detected with the influenza virus and other coronavirus N proteins. Patient nasopharyngeal samples were tested as part of a proof-of-concept clinical study where samples were also tested using the gold-standard real-time quantitative polymerase chain reaction (RT-qPCR) method. Preliminary results from a data set of 22 samples demonstrated a clinical specificity of 100% (n = 9 negative samples according to RT-qPCR) and a clinical sensitivity of 70% for samples with RT-PCR cycle threshold (Ct) values under 30 (n = 10) and 100% for samples with Ct values under 25 (n = 5), which complies with the World Health Organization (WHO) criteria for POC COVID-19 diagnostic tests. Our functionalized SPCEs were also validated against standard plaque assays, and very good agreement was found between both methods (R2 = 0.9993, n = 6), suggesting that our assay could be used to assess patient infectivity. The assay currently takes 70 min from sampling to results. © 2022 The Authors. Published by American Chemical Society. | |
dc.language | en | |
dc.publisher | American Chemical Society | |
dc.title | Electrochemical Immunoassay for the Detection of SARS-CoV-2 Nucleocapsid Protein in Nasopharyngeal Samples | |
dc.type | Article | |
dc.rights.holder | Scopus | |
dc.identifier.bibliograpycitation | Agriculture and Natural Resources. Vol 56, No.4 (2022), p.697-704 | |
dc.identifier.doi | 10.1021/acs.analchem.1c04966 | |
Appears in Collections: | Scopus 2022 |
Files in This Item:
There are no files associated with this item.
Items in SWU repository are protected by copyright, with all rights reserved, unless otherwise indicated.