Title: Electrochemical Capillary-Flow Immunoassay for Detecting Anti-SARS-CoV-2 Nucleocapsid Protein Antibodies at the Point of Care
Authors: Samper I.C.
Sánchez-Cano A.
Khamcharoen W.
Jang I.
Siangproh W.
Baldrich E.
Geiss B.J.
Dandy D.S.
Henry C.S.
Keywords: Antibodies
Blood
Blood vessels
Chemical detection
Diagnosis
Diseases
Electrodes
Immunology
Microfiltration
Recombinant proteins
Viruses
Capillary-flow device
Electrochemicals
Flow devices
Flow immunoassay
Nitrocellulose membranes
Nucleocapsid proteins
Point of care
Point of care diagnostic
Population levels
Sar-cov-2
SARS
nucleocapsid protein
virus antibody
human
immunoassay
point of care system
reproducibility
seroepidemiology
Antibodies, Viral
COVID-19
Humans
Immunoassay
Nucleocapsid Proteins
Point-of-Care Systems
Reproducibility of Results
SARS-CoV-2
Seroepidemiologic Studies
Issue Date: 2021
Abstract: Rapid and inexpensive serological tests for SARS-CoV-2 antibodies are needed to conduct population-level seroprevalence surveillance studies and can improve diagnostic reliability when used in combination with viral tests. Here, we report a novel low-cost electrochemical capillary-flow device to quantify IgG antibodies targeting SARS-CoV-2 nucleocapsid proteins (anti-N antibody) down to 5 ng/mL in low-volume (10 μL) human whole blood samples in under 20 min. No sample preparation is needed as the device integrates a blood-filtration membrane for on-board plasma extraction. The device is made of stacked layers of a hydrophilic polyester and double-sided adhesive films, which create a passive microfluidic circuit that automates the steps of an enzyme-linked immunosorbent assay (ELISA). The sample and reagents are sequentially delivered to a nitrocellulose membrane that is modified with a recombinant SARS-CoV-2 nucleocapsid protein. When present in the sample, anti-N antibodies are captured on the nitrocellulose membrane and detected via chronoamperometry performed on a screen-printed carbon electrode. As a result of this quantitative electrochemical readout, no result interpretation is required, making the device ideal for point-of-care (POC) use by non-trained users. Moreover, we show that the device can be coupled to a near-field communication potentiostat operated from a smartphone, confirming its true POC potential. The novelty of this work resides in the integration of sensitive electrochemical detection with capillary-flow immunoassay, providing accuracy at the point of care. This novel electrochemical capillary-flow device has the potential to aid the diagnosis of infectious diseases at the point of care. ©
URI: https://ir.swu.ac.th/jspui/handle/123456789/17476
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85118974642&doi=10.1021%2facssensors.1c01527&partnerID=40&md5=29c14b7bd467ff22f11c9464a118be8c
ISSN: 23793694
Appears in Collections:Scopus 1983-2021

Files in This Item:
There are no files associated with this item.


Items in SWU repository are protected by copyright, with all rights reserved, unless otherwise indicated.