Title: | Experimental study of the load-deformation behaviour of the precast post-tensioned continuous girder for straddle monorail: Full-scale load test under service and ultimate loading conditions |
Authors: | Sirisonthi A. Suparp S. Joyklad P. Hussain Q. Julphunthong P. |
Keywords: | Finite element method Load limits Load testing Loads (forces) Piers Reinforced concrete Computational tools Construction procedures Design and construction Engineering analysis Experimental program Service load condition Two point loadings Ultimate load-carrying capacity Beams and girders |
Issue Date: | 2021 |
Abstract: | This study presented the results of an experimental program conducted on a newly proposed Full-scale Precast Post-tensioned Continuous (FPPC) girder for straddle monorail. The investigated FPPC girder represents the actual size, design and construction details for a newly designed monorail transit system (Yellow Line and Pink Line Monorail) in Bangkok, Thailand. The salient features of the newly proposed girder system include lightweight, low-cost, easy and fast construction. The newly proposed FPPC girder is mainly comprised of three reinforced concrete (RC) hollow haunched girders, four piers or supports, two pier segments, four wet joints, and four bearings at each support. The FPPC girder was constructed at the casting yard of Sino-Thai Engineering and Construction Public Company Limited (STECON), Thailand. The FPPC girder was tested under different loading conditions (such as service and ultimate loading conditions). Both service and ultimate loads were applied as two-point loadings. Service load in a monotonic manner was applied on the right exterior span (two-point), middle span (two-point), and on the left exterior span and middle span (four-point). Meanwhile, the ultimate load in a monotonic manner was applied only on the left exterior and middle span as a four-point loading scheme. The test results indicate that the behaviour of the FPPC girder under service load conditions is elastic. Further, cracking of the concrete was not observed at any location. The observed maximum deflections under service load conditions were less than the permissible limits at all locations. Further, the maximum ultimate load-carrying capacity was observed to be much greater than the design load under ultimate loading conditions. This is an indication that the design details and construction procedure of FPPC girder are appropriate and further that this system could be used effectively to construct straddle monorail transit systems. Finite element analysis of FPPC monorail bridge girder was also performed by using a computer program ATENA which is a computational tool for nonlinear engineering analysis of bridges and culverts. The finite element analysis results indicate that the computer program ATENA is well capable to predict the ultimate load carrying capacity, displacement and cracking patterns of FPPC girder. © 2021 The Author(s) |
URI: | https://ir.swu.ac.th/jspui/handle/123456789/17365 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85113919104&doi=10.1016%2fj.cscm.2021.e00666&partnerID=40&md5=ff29d14013b9fb83e981e85082464ed1 |
ISSN: | 22145095 |
Appears in Collections: | Scopus 1983-2021 |
Files in This Item:
There are no files associated with this item.
Items in SWU repository are protected by copyright, with all rights reserved, unless otherwise indicated.