Please use this identifier to cite or link to this item: https://ir.swu.ac.th/jspui/handle/123456789/17206
Title: A multilayer microfluidic paper coupled with an electrochemical platform developed for sample separation and detection of dopamine
Authors: Khamcharoen W.
Siangproh W.
Keywords: Amines
Amino acids
Analytic equipment
Ascorbic acid
Cost effectiveness
Electrochemical sensors
Graphite electrodes
Microfluidics
Neurophysiology
Packing
Ultraviolet visible spectroscopy
ELectrochemical detection
Electrochemical platforms
Limit of detection
Microfluidic channel
Paper-based analytical devices
Screen-printed graphene electrodes
Selectivity and sensitivity
UV-vis spectroscopy
Chemical detection
Issue Date: 2021
Abstract: One of the primary challenges for the development of electrochemical sensors for dopamine (DA) is the lack of selectivity due to the major interference from ascorbic acid (AA) which is oxidized at a potential close to the working potential of DA. In this work, we present a means for simple and cost-effective electrochemical detection of DA in the presence of interference using a microfluidic paper-based analytical device (eμPAD) to improve the selectivity and sensitivity. The device was made by incorporating the sample separation and the electrochemical detection elements into a single device, which required a single drop of the sample solution. For sample separation, Nafion was cast on the sample zone and microfluidic channel to block AA, before the solution was allowed to continuously flow to the detection zone. A multilayered eμPAD was fabricated by placing a round cotton pad on the detection zone to enable the generation of a quasi-steady flow rate. Thereafter, a packing tape was used to seal the top part of the device to increase the flow rate and prevent volatilization of the sample on the eμPAD. The concentration of DA that could be measured by the poly(glutamic acid) modified screen-printed graphene electrode was in the range of 1-200 μM, and the limit of detection (LOD) was 0.41 μM (3SD/slope). The proposed platform provides an accurate and satisfactory method for the detection of DA in real samples compared with UV-Vis spectroscopy. © The Royal Society of Chemistry and the Centre National de la Recherche Scientifique 2021.
URI: https://ir.swu.ac.th/jspui/handle/123456789/17206
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85111354663&doi=10.1039%2fd1nj02271g&partnerID=40&md5=89918b3ee26c4ac9008a2f63df965dd3
ISSN: 11440546
Appears in Collections:Scopus 1983-2021

Files in This Item:
There are no files associated with this item.


Items in SWU repository are protected by copyright, with all rights reserved, unless otherwise indicated.