Please use this identifier to cite or link to this item: https://ir.swu.ac.th/jspui/handle/123456789/17177
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAhmad H.
dc.contributor.authorElnemr A.
dc.contributor.authorAli N.
dc.contributor.authorHussain Q.
dc.contributor.authorChaiyasarn K.
dc.contributor.authorJoyklad P.
dc.date.accessioned2022-03-10T13:16:36Z-
dc.date.available2022-03-10T13:16:36Z-
dc.date.issued2021
dc.identifier.issn20734360
dc.identifier.other2-s2.0-85121723054
dc.identifier.urihttps://ir.swu.ac.th/jspui/handle/123456789/17177-
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85121723054&doi=10.3390%2fpolym13244468&partnerID=40&md5=a94aabfd0c1a0df4ca75d9af65f4315f
dc.description.abstractFiber-reinforced concrete (FRC) is a competitive solution for the durability of reinforced structures. This paper aims to observe the moment redistribution behavior occurring due to flexural and shear loading in Glass Fiber-Reinforced Polymer-(GFRP) reinforced continuous concrete beams. A rectangular cross-section was adopted in this study with dimensions of 200 mm in width and 300 mm in depth with a constant shear span-to-depth ratio of 3. The reinforcement ratio for the top and bottom were equal at sagging and hogging moment regions. A finite element model was created using Analysis System (ANSYS) and validated with the existing experimental results in the literature review. Based on the literature review, the parametric study was conducted on twelve beam specimens to evaluate the influence of concrete compressive strength, transversal GFRP stirrups ratio, and longitudinal reinforcement ratio on the redistribution of the moment in beams. Several codes and guidelines adopted different analytical models. The Canadian Standards Association (CSA) S806 adopted the modified compression field theory in predicting the shear capacity of the simply supported beams. Recently, various researchers encountered several factors and modifications to account for concrete contribution, longitudinal, and transverse reinforcement. A comparison between the predicting shear capacity of the generated finite element model, the analytical model, and the existing data from the literature was performed. The generated finite element model showed a good agreement with the experimental results, while the beam specimens failed in shear after undergoing significant moment redistribution from hogging to sagging moment region. The moment distribution observed about 21.5% from FEM of beam specimen GN-1.2-0.48-d, while the experimental results achieved 24% at failure load. For high strength concrete presented in beam specimen GH-1.2-0.63-d, the result showed about 20.2% moment distribution, compared to that achieved experimentally of 23% at failure load. © 2021 by the authors. Licensee MDPI, Basel, Switzerland.
dc.languageen
dc.subjectAnalytical models
dc.subjectBridge decks
dc.subjectCompressive strength
dc.subjectConcrete beams and girders
dc.subjectGlass fibers
dc.subjectHigh performance concrete
dc.subjectReinforced concrete
dc.subjectConcrete beam
dc.subjectContinuous beams
dc.subjectFinite element modelling (FEM)
dc.subjectGlassfiber reinforced polymers (GFRP)
dc.subjectMoment redistribu-tion
dc.subjectMoment redistribution
dc.subjectReinforcement ratios
dc.subjectSagging moment
dc.subjectShear capacity
dc.subjectStirrup
dc.subjectFinite element method
dc.titleFinite element analysis of glass fiber-reinforced polymer-(Gfrp) reinforced continuous concrete beams
dc.typeArticle
dc.rights.holderScopus
dc.identifier.bibliograpycitationPolymers. Vol 13, No.24 (2021)
dc.identifier.doi10.3390/polym13244468
Appears in Collections:Scopus 1983-2021

Files in This Item:
There are no files associated with this item.


Items in SWU repository are protected by copyright, with all rights reserved, unless otherwise indicated.